logo
Home ProductsOxygen Gas Sensor

AO2 PTB-18.10 Highly Stable Oxygen Gas Sensor For Oxygen Alarm Devices

I'm Online Chat Now

AO2 PTB-18.10 Highly Stable Oxygen Gas Sensor For Oxygen Alarm Devices

AO2 PTB-18.10 Highly Stable Oxygen Gas Sensor For Oxygen Alarm Devices
AO2 PTB-18.10 Highly Stable Oxygen Gas Sensor For Oxygen Alarm Devices AO2 PTB-18.10 Highly Stable Oxygen Gas Sensor For Oxygen Alarm Devices AO2 PTB-18.10 Highly Stable Oxygen Gas Sensor For Oxygen Alarm Devices AO2 PTB-18.10 Highly Stable Oxygen Gas Sensor For Oxygen Alarm Devices AO2 PTB-18.10 Highly Stable Oxygen Gas Sensor For Oxygen Alarm Devices AO2 PTB-18.10 Highly Stable Oxygen Gas Sensor For Oxygen Alarm Devices AO2 PTB-18.10 Highly Stable Oxygen Gas Sensor For Oxygen Alarm Devices

Large Image :  AO2 PTB-18.10 Highly Stable Oxygen Gas Sensor For Oxygen Alarm Devices

Product Details:
Place of Origin: USA
Model Number: AO2
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Standard packaging
Delivery Time: 3-5workingdays
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 5000PCS

AO2 PTB-18.10 Highly Stable Oxygen Gas Sensor For Oxygen Alarm Devices

Description
Range: 0-100% O2 Resolution: 0.01% O2
T90 Response Time: <5 Seconds Output: 9 - 13mV In Air
T99.5 Response Time*: <40 Seconds Signal In 100%O2: 100±1%
Highlight:

Molex connector Oxygen Gas Sensor

,

Highly Stable Oxygen Gas Sensor

,

AO2 Oxygen Gas Sensor

 

                        AO2 PTB-18.10 Highly Stable Oxygen Gas Sensor For Oxygen Alarm Devices

 

Application Fields:

  • Motor vehicle exhaust gas detection equipment.
  • Exhaust gas environmental protection detection equipment.
  • Oxygen index testing equipment.
  • Oxygen alarm devices.
  • Safety oxygen monitoring systems in coal mines, steel, and petrochemical fields.

Installation and Usage Precautions:

  • Avoid exposure to high - concentration solvent vapors during storage, installation, and operation.
  • When using sensors with printed circuit boards, degreasing agents should be used before installation. Do not glue directly on or near the critical part as the solvent may cause crazing of the plastic.
  • When installing the sensor, it must only be screwed in by hand to ensure a gas - tight seal. Do not use spanners or similar mechanical aids to avoid damaging the sensor thread.

 

Type Oxygen Sensor
Operating Principle Electrochemical (Partial Pressure)
Measurement Range 0 - 100% Oxygen (at atmospheric pressure)
Output 9 - 13 mV in air
Response Time (T90) < 5 s
Response Time (T99.5) < 40 s
Zero Bias < 20 μV
Operating Temperature Range - 20 °C to + 50 °C
Temperature Compensation < 2% variation (0 - 40 °C)
Differential Pressure Range 0 - 500 mbar
Absolute Pressure Range 500 - 2000 mbar (0.5 - 2.0 bar)
Relative Humidity Range 0 - 99% non - condensing
Long - term Output Drift < 10% signal loss per year
Load Resistance 10 kΩ
Housing Material Red ABS
Weight 40 g
Connector 3 - pin Molex
Expected Service Life 2 years in air

 

AO2 PTB-18.10 Highly Stable Oxygen Gas Sensor For Oxygen Alarm Devices 0

 

Contact Details
ShenzhenYijiajie Electronic Co., Ltd.

Contact Person: Miss. Xu

Tel: 86+13352990255

Send your inquiry directly to us (0 / 3000)