Product Details:
Brand Name: MEMBRAPOR
Model Number: Alc/C-100
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard Box
Delivery Time: 3-5Workingdays
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 5000PCS/Month

Alc/C-100 Alcohol Gas Sensor 100 ppm Continuous Air Quality Monitoring

Description
Operation Principle: 3-Electrode Electrochemical Nominal Range: 0 - 100 Ppm
Maximum Overload: 200 Ppm Resolution: < 0.05 Ppm
T90 Response Time: < 25 S Typical Baseline Range (pure Air, 20°C): 0.4 Ppm To 1.4 Ppm
Maximum Zero Shift (+20°C To +40°C): See Graph Repeatability: < 2 % Of Signal
Highlight:

C-100 Alcohol Gas Sensor

,

Alcohol Gas Sensor 100 ppm

Alc/C-100 Alcohols Gas Sensor Continuous Air Quality Monitoring

 

Performance data recorded at 20 – 25 °C, 30 - 50% RH, 900 - 1100 mbar
For further information about usage of Membrapor sensors, see application note MEM1. The data
contained in this document is for guidance only. Membrapor AG accepts no liability for any
consequential losses, injury or damage resulting from the use of this document or from any
omissions or errors herein. Customers should test under their own conditions to ensure that the
sensors are suitable for their own requirements.

Rec. Load Resistor 10 - 33 Ω
Bias (V_Sens-V_Ref) +300 mV
Relative Humidity Range 15 % to 90 % RH non-condensing
Temperature Range -40 °C to 50 °C
Pressure Range Atmospheric ± 10%
Pressure Coefficient N.D.
Humidity Effect None
Expected Operation Life 2 years in air
Expected Long Term Output Drift in air < 2 % signal loss per month
Storage Life 6 months in container
Rec. Storage Temperature 5°C - 20°C
Warranty Period 12 months from date of dispatch

 

Temperature dependence
The output of an electrochemical sensor varies with temperature. The graphs below show the temperature-dependent variation of baseline and sensitivity, respectively. The results shown here are raw data (batch average) without any post-processing steps.                                                The sensitivity and baseline are referenced to the signal at 20°C (reference point).
Please note: It is highly recommended to acquire the temperature dependence curves with
the whole instrument. The sampling system, the humidity, the electronics and the interaction
between the electronics and the sensor have a significant impact on the temperature
dependence of the final measurement reading.

Alc/C-100 Alcohol Gas Sensor 100 ppm Continuous Air Quality Monitoring 0

Alc/C-100 Alcohol Gas Sensor 100 ppm Continuous Air Quality Monitoring 1

 

Alc/C-100 Alcohol Gas Sensor 100 ppm Continuous Air Quality Monitoring 2

Contact Details
ShenzhenYijiajie Electronic Co., Ltd.

Contact Person: Xu

Tel: 86+13352990255

Send your inquiry directly to us (0 / 3000)