Send Message
Home ProductsGas Sensor

4CL2-50 Chlorine Dioxide Sensor Electrochemical For Chlorine Concentration Detection

I'm Online Chat Now

4CL2-50 Chlorine Dioxide Sensor Electrochemical For Chlorine Concentration Detection

4CL2-50 Chlorine Dioxide Sensor Electrochemical For Chlorine Concentration Detection
4CL2-50 Chlorine Dioxide Sensor Electrochemical For Chlorine Concentration Detection
4CL2-50 Chlorine Dioxide Sensor Electrochemical For Chlorine Concentration Detection 4CL2-50 Chlorine Dioxide Sensor Electrochemical For Chlorine Concentration Detection 4CL2-50 Chlorine Dioxide Sensor Electrochemical For Chlorine Concentration Detection

Large Image :  4CL2-50 Chlorine Dioxide Sensor Electrochemical For Chlorine Concentration Detection

Product Details:
Place of Origin: Britain
Brand Name: CITY
Model Number: 4CL2-50
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: canned
Delivery Time: 3-5work days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 311/pcs/pre

4CL2-50 Chlorine Dioxide Sensor Electrochemical For Chlorine Concentration Detection

Description
Maximum Current At 100 PPM Chlorine Gas: 0.2 MA Maximum Open Circuit Voltage: 1.3V
Maximum Short-circuit Current:: 1.0A Physical Properties Of Shell Material: ABS
Weight Of The: 5g Bearing: There Is No
Highlight:

4CL2-50 Chlorine Dioxide Sensor

,

Chlorine Dioxide Sensor Electrochemical

Product Description:

4CL2-50 Series Chlorine Dioxide Electrochemical Chlorine Sensor Is Used For Chlorine Concentration Detection

 

Features:

 

This product is used to measure chlorine gas concentration and can be replaced by a standard four-series electrochemical chlorine sensor with a pin.

The performance parameters

Range: 0~50 PPM

Maximum load: 100 PPM

Sensitivity (20℃) : 0.45 ± 0.2 μA/ PPM

Response time (T90) : ≤ 30s

Baseline (20℃) : < Plus or minus 0.02 mu A

Baseline drift (-20 ℃ ~ 50 ℃) : < 0.3 parts per million

Resolution: 0.1 PPM

Linearity: linearity

Bias voltage: 0 mV

The work environment

Temperature range: -20 ° C to 50 ° C

Pressure range: one standard atmosphere ± 10%

Humidity range: 15%-95%RH (non-condensing)

 

Specifications:

Long-term stability < 2% signal value/year
Storage temperature 10 ℃ ~ 30 ℃
The service life of the 2 years (in air)
Storage time 6 months (in special boxes)
The quality assurance period 12 months