Send Message
Home ProductsOxygen Gas Sensor

Fluorescence Quenching Oxygen Gas Sensor LOX-02 TTL Digital Signal Output

I'm Online Chat Now

Fluorescence Quenching Oxygen Gas Sensor LOX-02 TTL Digital Signal Output

Fluorescence Quenching Oxygen Gas Sensor LOX-02 TTL Digital Signal Output
Fluorescence Quenching Oxygen Gas Sensor LOX-02 TTL Digital Signal Output Fluorescence Quenching Oxygen Gas Sensor LOX-02 TTL Digital Signal Output Fluorescence Quenching Oxygen Gas Sensor LOX-02 TTL Digital Signal Output Fluorescence Quenching Oxygen Gas Sensor LOX-02 TTL Digital Signal Output

Large Image :  Fluorescence Quenching Oxygen Gas Sensor LOX-02 TTL Digital Signal Output

Product Details:
Place of Origin: UK
Brand Name: SST
Model Number: LOX-02
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard Box
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

Fluorescence Quenching Oxygen Gas Sensor LOX-02 TTL Digital Signal Output

Description
Supply Voltage (Vs): 4.5~5.5Vdc Supply Current (Is): <7.5mA (1Hz Data Sampling Rate)
Output Type: 3.3VTTL Level RS232 Working Temperature: -30℃ ~ +60℃
Storage Temperature: -30℃ ~ +60℃ Humidity: 0~99% (non-condensing)
Pressure Range: 500~1200mbar
Highlight:

Oxygen Gas Sensor LOX-02

,

Oxygen Gas Sensor TTL

,

Fluorescence Quenching Oxygen Sensor

LOX-02 O2 Fluorescent Oxygen Sensor TTL Digital Signal Output

 

LuminOx is an oxygen sensor that uses the principle of fluorescence quenching and factory calibration to measure ambient partial pressure of oxygen (ppO2).

 

LuminOx measures oxygen partial pressure and temperature. The addition of a barometric pressure sensor allows the sensor to output the oxygen concentration value and barometric pressure value; combined with the traditional low power consumption advantages of electrochemical sensors, the non-consumption sensing principle makes it have a longer life.

 

The LuminOx is oxygen pressure and temperature compensated, allowing it to work accurately over a wide range of environments without the need for additional compensation systems. Unlike other sensor technologies, LuminOx is very stable and environmentally friendly, does not contain lead or any other toxic materials, and is immune to cross-interference from other gases.

 

Specification Sheet:

Oxygen measurement range 0~25% (Lox-02), 0-300mbar (ppO2)
Response time T90 <30s (typ.)
Accuracy/resolution <2%FS/0.1mbar
Temperature Accuracy/Resolution Indication Only/0.1℃
Pressure accuracy/resolution ± 5mbar/1mbar (Lox-02)
O2% accuracy/resolution Determined by PPO2 and pressure
Accuracy 0.1% (Lox-02)
Lifetime >5 years

 

Fluorescence Quenching Oxygen Gas Sensor LOX-02 TTL Digital Signal Output 0

Contact Details
ShenzhenYijiajie Electronic Co., Ltd.

Contact Person: Xu

Tel: 86+13352990255

Send your inquiry directly to us (0 / 3000)