Send Message
Home ProductsOxygen Gas Sensor

MOX4 MOX-4 Oxygen Gas Sensor Medical Equipment White ABS AA829-M20 Oxygen Battery

I'm Online Chat Now

MOX4 MOX-4 Oxygen Gas Sensor Medical Equipment White ABS AA829-M20 Oxygen Battery

MOX4 MOX-4 Oxygen Gas Sensor Medical Equipment White ABS AA829-M20 Oxygen Battery
MOX4 MOX-4 Oxygen Gas Sensor Medical Equipment White ABS AA829-M20 Oxygen Battery MOX4 MOX-4 Oxygen Gas Sensor Medical Equipment White ABS AA829-M20 Oxygen Battery

Large Image :  MOX4 MOX-4 Oxygen Gas Sensor Medical Equipment White ABS AA829-M20 Oxygen Battery

Product Details:
Place of Origin: Britain
Brand Name: CITY
Model Number: MOX-4 MOX4 AA829-M20
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: canned
Delivery Time: 3-5work days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 311/pcs/pre

MOX4 MOX-4 Oxygen Gas Sensor Medical Equipment White ABS AA829-M20 Oxygen Battery

Description
Temperature Compensation: Partial Compensation For Teledyne T-7 Equivalence External Load Resistor: 10 KΩ Min.
Connector: UK Data Socket AMP (P/N 520257-2) Housing Material: White ABS
Weight: 42 G (nominal) Orientation: Any
Highlight:

MOX-4 Oxygen Gas Sensor

,

Oxygen Gas Sensor White ABS

,

MOX4 Oxygen Sensor Medical Equipment

Product Description:

MOX-4 MOX4 AA829-M20 OxygenSensor Oxygen Battery For Medical Equipment

 

Features:

The purpose of this document is to present the performance specification of the MOX4 oxygen gas sensor.

This document should be used in conjunction with the Operating Principles (OP04) and the Product Safety Datasheet (PSDS 4).

The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3 months from the date of sensor manufacture.

Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP04).

Poisoning

CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation.

When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.

Intended Use

These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not including xenon), critical care, neonatal incubators and general oxygen monitors

 

Specifications:

Operating Principle Partial pressure electrochemical
Output 9 mV to 13 mV in 210 mBar O2
Measurement Range 0 mBar to 1500 mBar O2
Response Time (T90)* <15 s (air to 100% O2)
Baseline Offset* <200 μV
Linearity Linear 0% to 100% O2

 

 