Product Details:
|
Operating Principle: | 3 Electrode Electrochemical | Measurement Range: | 0-1ppm AsH3 |
---|---|---|---|
Maximum Overload: | 20PPM | Lower Detection Limit: | <30PPB When Using |
Highlight: | 0731 337 30047 Gas Sensor,ASH3 3E 1 Gas Sensor,0731 337 30047 |
ASH3 3E 1 LT 7060169 B2 Gas Sensor 3 Electrode Electrochemical Excellent stability
Poisoning
Sensoric cells are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments, and operation.
When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the Sensoric cells as the solvent may cause crazing of the plastic.
Dataheet:
Sensitivity | 1400±450nAm ppm |
Respond Time(T90s) | <30 Seconds |
Baseline Ofifiset(clean air) | <±20nA |
Zero Shifit_-40℃ to 50℃) | <40ppb |
Repeatability |
<2% of signal |
Contact Person: Xu
Tel: 86+13352990255