logo
Send Message
  • English
Home ProductsGas Sensor

H2S 2000 Sensitivity Gas Sensor for 0-2000 Ppm Measurement Range 60 25 NA/ppm 10 Ohm Load Resistor

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

H2S 2000 Sensitivity Gas Sensor for 0-2000 Ppm Measurement Range 60 25 NA/ppm 10 Ohm Load Resistor

H2S 2000 Sensitivity Gas Sensor for 0-2000 Ppm Measurement Range 60 25 NA/ppm 10 Ohm Load Resistor
H2S 2000 Sensitivity Gas Sensor for 0-2000 Ppm Measurement Range 60 25 NA/ppm 10 Ohm Load Resistor H2S 2000 Sensitivity Gas Sensor for 0-2000 Ppm Measurement Range 60 25 NA/ppm 10 Ohm Load Resistor H2S 2000 Sensitivity Gas Sensor for 0-2000 Ppm Measurement Range 60 25 NA/ppm 10 Ohm Load Resistor H2S 2000 Sensitivity Gas Sensor for 0-2000 Ppm Measurement Range 60 25 NA/ppm 10 Ohm Load Resistor H2S 2000 Sensitivity Gas Sensor for 0-2000 Ppm Measurement Range 60 25 NA/ppm 10 Ohm Load Resistor H2S 2000 Sensitivity Gas Sensor for 0-2000 Ppm Measurement Range 60 25 NA/ppm 10 Ohm Load Resistor

Large Image :  H2S 2000 Sensitivity Gas Sensor for 0-2000 Ppm Measurement Range 60 25 NA/ppm 10 Ohm Load Resistor

Product Details:
Place of Origin: Germany
Brand Name: SensoriX
Model Number: H2S 2000
Payment & Shipping Terms:
Packaging Details: Standard Package
Delivery Time: 3-5workingdays
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

H2S 2000 Sensitivity Gas Sensor for 0-2000 Ppm Measurement Range 60 25 NA/ppm 10 Ohm Load Resistor

Description
Repeatability: < 2% Recommended Load Resistor: 10 Ohm
Measurement Range: 0-2000 Ppm Response Time(T90): ≤ 60s At 2 Min Gas Exposure
Pressure Range: 800-1200 HPa Humidity Range: 15% To 90% R.h. Non-condensing
Sensitivity: 60+25 NA/ppm Temperature Range: -20°C To +50°C
Highlight:

10 Ohm Load Resistor Gas Sensor

,

0-2000 Ppm Gas Sensor

,

H2S 2000 Sensitivity Gas Sensor

Product Description:

 

Features:

  • Product Name: Gas Sensor
  • Measurement Range: 0-2000 Ppm
  • Response Time(T90): ≤ 60s At 2 Min Gas Exposure
  • Recommended Load Resistor: 10 Ohm
  • Sensitivity: 60+25 NA/ppm
  • Pressure Range: 800-1200 HPa
  • Expected sensor life > 4 years
  • New
  • LEL
 

Technical Parameters:

Sensitivity 60+25 NA/ppm
Bias Voltage 0 V
Measurement Range 0-2000 Ppm
Response Time(T90) ≤ 60s At 2 Min Gas Exposure
Pressure Range 800-1200 HPa
Temperature Range -20°C To +50°C
Humidity Range 15% To 90% R.h. Non-condensing
Baseline (in clean air) <± 250 NA
Recommended Load Resistor 10 Ohm
Repeatability < 2%
 

Applications:

<± 250 NA and a recommended load resistor of 10 Ohm, this sensor is capable of detecting even trace amounts of H2S in the air.

The SensoriX H2S 2000 gas sensor is ideal for a wide range of applications and scenarios. It can be used in industrial settings to detect gas leaks and ensure worker safety. It is also suitable for use in laboratories and research facilities where precise gas detection is required.

Another common application of the SensoriX H2S 2000 gas sensor is in the oil and gas industry, where it can be used to detect LEL (Lower Explosive Limit) levels of H2S. This is important for ensuring the safety of workers and preventing explosions or other accidents.

The SensoriX H2S 2000 gas sensor is highly sensitive, with a sensitivity of 60+25 NA/ppm and a repeatability of < 2%. It also has a fast response time, with a T90 of ≤ 60s at 2 min gas exposure. This makes it an ideal choice for applications where quick and accurate detection of H2S is essential.

In summary, the SensoriX H2S 2000 gas sensor is a reliable and accurate tool for detecting H2S gas in a variety of settings. Whether you are working in an industrial setting, a laboratory, or the oil and gas industry, this sensor is a valuable addition to your toolkit.

 

Customization:

With our product customization services, you can get a brand new SensoriX H2S 2000 gas sensor tailored to your specific needs. Whether you need a different temperature range, baseline, or sensitivity, we can customize your sensor to meet your requirements.

Our gas sensors are perfect for detecting LEL levels of H2S, and can be used in a variety of applications. Order now and receive a 10% discount by using the code 6812950 at checkout.

 

Packing and Shipping:

Product Packaging:

  • Gas sensor
  • User manual
  • Mounting screws and brackets
  • Power adapter

Shipping:

  • Shipped via FedEx
  • Tracking number provided
  • Estimated delivery time: 3-5 business days
  • Shipping cost calculated at checkout
 

FAQ:

Here are the frequently asked questions and answers for SensoriX's H2S 2000 Gas Sensor:

Q: What is SensoriX's H2S 2000 Gas Sensor?

A: SensoriX's H2S 2000 Gas Sensor is a device designed to detect the presence of hydrogen sulfide gas in the air.

Q: What is the range of detection for SensoriX's H2S 2000 Gas Sensor?

A: The range of detection for SensoriX's H2S 2000 Gas Sensor is 0-100 ppm (parts per million).

Q: What is the response time for SensoriX's H2S 2000 Gas Sensor?

A: The response time for SensoriX's H2S 2000 Gas Sensor is less than 30 seconds.

Q: Where is SensoriX's H2S 2000 Gas Sensor manufactured?

A: SensoriX's H2S 2000 Gas Sensor is manufactured in Germany.

Q: What is the warranty for SensoriX's H2S 2000 Gas Sensor?

A: Please see the warranty information provided with your purchase of SensoriX's H2S 2000 Gas Sensor for specific details.

Contact Details
ShenzhenYijiajie Electronic Co., Ltd.

Contact Person: Xu

Tel: 86+13352990255

Send your inquiry directly to us (0 / 3000)