Product Details:
|
Nominal Range: | 0 - 100 Ppm | Maximum Overload: | 200 Ppm |
---|---|---|---|
Output Signal: | Methanol: 1600 ± 600 NA/ppm | Resolution (Electronics Dependent): | < 0.05 Ppm |
T90 Response Time: | < 25 S | Typical Baseline Range (pure Air, 20°C): | 0.4 Ppm To 1.4 Ppm 1) |
Highlight: | Compact Housing Gas Sensor,Electrochemical Alcohols Gas Sensor |
Alc/C-100 3-Electrode Electrochemical Alcohols Gas Sensor R3COH Gas Sensor In Compact Housing
Applications:
• Continuous Air Quality Monitoring
• Safety and Process Control
Electrical:
Rec. Load Resistor: 10 - 33 Ω
Bias (V_Sens-V_Ref): +300 mV
Conformity to RoHS directive :RoHS Compliance
Environmental:
Relative Humidity Range :15 % to 90 % RH non-condensing
Temperature Range : -40 °C to 50 °C Pressure Range Atmospheric
Pressure Coefficient : N.D.
Humidity Effect : None
Expected Operation Life | 2 years in air |
Expected Long Term Output Drift in air | < 2 % signal loss per month |
Filter Life | not applicable |
Storage Life | 6 months in container |
Rec. Storage Temperature | 5°C - 20°C |
Contact Person: Miss. Xu
Tel: 86+13352990255