logo
Home ProductsGas Sensor

Mipex-02-1-II-1.1A Infrared Gas Sensor For Detecting Methane (CH4) Concentration

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

Mipex-02-1-II-1.1A Infrared Gas Sensor For Detecting Methane (CH4) Concentration

Mipex-02-1-II-1.1A Infrared Gas Sensor For Detecting Methane (CH4) Concentration
Mipex-02-1-II-1.1A Infrared Gas Sensor For Detecting Methane (CH4) Concentration

Large Image :  Mipex-02-1-II-1.1A Infrared Gas Sensor For Detecting Methane (CH4) Concentration

Product Details:
Place of Origin: Russia
Model Number: Mipex-02-1-II-1.1A
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Paper box
Delivery Time: 3-5work days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 5000pcs

Mipex-02-1-II-1.1A Infrared Gas Sensor For Detecting Methane (CH4) Concentration

Description
Relative Humidity: 98% Atmospheric Pressure: 80 - 120 Kpa
Temperature: -10 To +40 °C (Group I); -40 To +60 °C (Group II) Overall Dimensions: Φ20x16.6mm
Detected Gases: CH4 Response Time T90: <10s (fast Version); <30s.
Highlight:

Methane gas sensor 1.1A

,

Infrared CH4 concentration detector

,

Gas sensor with warranty

 

                              Mipex-02-1-II-1.1A Infrared Gas Sensor For Detecting Methane (CH4) Concentration 

 

1. Product Features:

  • Ultra-low power consumption: Average power consumption is less than 5 mW, ideal for battery-powered portable detection devices and scenarios requiring long-term continuous operation.
  • Wide measurement range & high accuracy: Supports measuring up to 100% VOL methane (CH₄) and 100% LEL hydrocarbon (CₙHₘ, calibrated to propane C₃H₈); accuracy reaches ±0.1% VOL or 5% of reading for CH₄, and ±3% LEL or 5% of reading for C₃H₈, meeting strict industrial detection standards.
  • Strong environmental adaptability: Operates normally under relative humidity up to 98% (non-condensing) and temperature ranges of -10~+40°C (Group I) / -40~+60°C (Group II); almost no interference from humidity, suitable for harsh industrial and mining environments.
  • High safety level: Complies with multiple international explosion-proof standards (e.g., Ex ia I Ma/Ex ia IIC T5 Ga, UL913 Class I Division 1); features "ia" intrinsic safety protection without sintering, ensuring safe use in flammable and explosive areas.
  • Stable & low-maintenance: Resistant to "poisoning" gases that affect catalytic sensors; maintains long-term stability with simple calibration requirements, reducing equipment maintenance frequency and costs.
  • Easy integration: Built-in microcontroller and digital UART interface; compact size (Φ20x16.6mm without pins) and lightweight (5.5~16.6g based on material), enabling easy integration into various detection instruments and systems.

2. Product Applications:

  • Mining industry: Used in underground coal mines and metal mines to detect methane (CH₄) leaks, preventing gas explosions and ensuring the safety of underground operations and personnel.
  • Oil & gas sector: Applied in oil exploration sites, refineries, and natural gas pipelines to monitor hydrocarbon (CₙHₘ) and methane concentrations, avoiding fire or explosion risks from gas leaks.
  • Chemical & petrochemical industry: Integrated into safety monitoring systems of chemical plants and petrochemical facilities to track methane and carbon dioxide (CO₂) emissions, ensuring compliance with environmental and occupational health standards.
  • Power & utility industry: Used in power plants, water treatment plants, and wastewater treatment facilities to detect flammable gas leaks in equipment operation environments, protecting production safety.
  • Portable detection devices: Assembled into handheld gas detectors for on-site emergency testing in hazardous material (hazmat) handling, fire rescue, and biogas engineering scenarios, providing real-time gas concentration data.

Parameter

Description

Working Principle NDIR (Non - Dispersive Infrared)
Gas Sampling Method Diffusion
Detected Gases CH4 (with reduced cross - sensitivity to ethane), CnHm (calibrated to C3H8), CO2
Measurement Range Up to 100%VOL CH4; 100%LEL CnHm
Accuracy ±0.1%vol. or 5% of the reading value for CH4; ±3%LEL. or ±5% of the reading value for C3H8
Response Time T90 <10s (fast version); <30s
Working Power Supply Voltage 3.0 - 5.0 VDC
Output Signal Digital, UART
Power Consumption <5mW
Warm - up Time No more than 1 min
Relative Humidity Up to 98%
Atmospheric Pressure 80 - 120 Kpa
Temperature -10 to +40 °C (Group I); -40 to +60 °C (Group II)
Overall Dimensions Φ20x16.6mm (without pins)
Weight Stainless steel (standard) - 16.6g; Stainless steel (fast version) - 15.5g; Polycarbonate - 5.5g

 

Mipex-02-1-II-1.1A Infrared Gas Sensor For Detecting Methane (CH4) Concentration 0

Contact Details
ShenzhenYijiajie Electronic Co., Ltd.

Contact Person: Miss. Xu

Tel: 86+13352990255

Send your inquiry directly to us (0 / 3000)