Product Details:
|
Operation Principle: | 3-Electrode Electrochemical | Nominal Range: | 0 - 10 Ppm |
---|---|---|---|
Maximum Overload: | 50 Ppm | Output Signal: | 4600 ± 1200 NA/ppm |
Resolution (Electronics Dependent): | < 0.01 Ppm | T60 Response Time: | < 30 S |
Typical Baseline Range (pure Air, 20°C): | -0.1 Ppm To 0.1 Ppm | Maximum Zero Shift (+20°C To +40°C): | 0.3 Ppm |
Repeatability: | < 2 % Of Signal | ||
Highlight: | CH2O Formaldehyde Gas Sensor,Formaldehyde Gas Sensor Highly Sensitive,C-10 CH2O Sensor |
CH2O/C-10 Formaldehyde Gas Sensor Highly Sensitive CH2O Measurement
Applications
• Continuous Air Quality Monitoring
• Safety and Environmental Control
Specification Sheet
Rec. Load Resistor | 10 - 33 Ω |
Bias (V_Sens-V_Ref) | not recommended |
Relative Humidity Range | 15 % to 90 % RH non-condensing |
Temperature Range | -40 °C to 50 °C |
Pressure Range | Atmospheric ± 10% |
Pressure Coefficient | N.D. |
Humidity Effect | Abrupt changes in RH causes a short term transient signal |
Expected Operation Life | 3 years in air |
Expected Long Term Output Drift in air | < 2 % signal loss per month |
Storage Life | 6 months in container |
Rec. Storage Temperature | 5°C - 20°C |
Warranty Period | 12 months from date of dispatch |
Formaldehyde Gas Sensor CH2O/C-10
Cross Sensitivity Data
The table below does not claim to be complete. Interfering gases should not be used for
calibration. Please contact Membrapor AG for further support regarding cross sensitivities.