Product Details:
|
Nominal Range: | 0-1000ppm | Maximum Overload: | 2000ppm |
---|---|---|---|
Expected Operating Life: | Two Years In Air | Output Signal: | 0.015 ± 0.01 μA/ppm |
Resolution: | 2ppm | Temperature Range: | -20°C To +50°C |
Pressure Range: | Atmospheric ± 10% | T90 Response Time: | <90 Seconds |
Product Description:
4HYT Four-series Hydrogen Sensor Is used In The Industrial Safety Field
Features:
CiTiceLs may exhibit a response to certain gases in a sample other than the target gas. 4HYT CiTiceLs have been
tested with a number of commonly cross-interfering gases and the results are given below. The table shows the typical
response to be expected from a sensor when exposed to a given test gas concentration (relevant to safety, e.g. TLV
levels).
Gas Conc. 4HYT Gas Conc. 4HYT
Carbon monoxide: 300ppm ≤60ppm Chlorine: 1ppm 0ppm
Hydrogen sulphide: 15ppm <3ppm Hydrogen cyanide: 10ppm ≈3ppm
Sulphur dioxide: 5ppm 0ppm Hydrogen chloride: 5ppm 0ppm
Nitric oxide: 35ppm ≈10ppm Ethylene: 100ppm ≈80ppm
Nitrogen dioxide: 5ppm 0ppm **For details of other possible cross-interfering gases contact City Technology
Specifications:
Output Linearity | Linear |
Weight | 5g (approx.) |
Position Sensitivity | None |
Storage Life | Six months in CTL container |
Recommended Storage Temperature |
0-20°C |
Warranty Period |
12 months from date of despatch |
Contact Person: Xu
Tel: 86+13352990255