logo
Send Message
  • English
Home ProductsGas Sensor

5ND AG526-W00 Electrochemical Nitrogen Dioxide Gas Sensor 3 Electrode electrochemical For Waste Gas

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

5ND AG526-W00 Electrochemical Nitrogen Dioxide Gas Sensor 3 Electrode electrochemical For Waste Gas

5ND AG526-W00 Electrochemical Nitrogen Dioxide Gas Sensor 3 Electrode electrochemical For Waste Gas
5ND AG526-W00 Electrochemical Nitrogen Dioxide Gas Sensor 3 Electrode electrochemical For Waste Gas
5ND AG526-W00 Electrochemical Nitrogen Dioxide Gas Sensor 3 Electrode electrochemical For Waste Gas 5ND AG526-W00 Electrochemical Nitrogen Dioxide Gas Sensor 3 Electrode electrochemical For Waste Gas 5ND AG526-W00 Electrochemical Nitrogen Dioxide Gas Sensor 3 Electrode electrochemical For Waste Gas

Large Image :  5ND AG526-W00 Electrochemical Nitrogen Dioxide Gas Sensor 3 Electrode electrochemical For Waste Gas

Product Details:
Place of Origin: UK
Brand Name: CITY
Model Number: 5ND
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Canned
Delivery Time: 3-5work days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 1000pcs/Month

5ND AG526-W00 Electrochemical Nitrogen Dioxide Gas Sensor 3 Electrode electrochemical For Waste Gas

Description
Maximum Zero Shift: -1ppm Equivalent Long Term Output Drift: <2% Signal Loss/month
Recommended Load: 33 Ω Bias Voltage: Not Required
Repeatability: 2% Of Signal Output Linearity: Linear
Highlight:

Waste Gas Nitrogen Dioxide Gas Sensor

,

5ND AG526-W00 Nitrogen Dioxide Gas Sensor

Product Description:

5ND AG526-W00 Electrochemical Nitrogen Dioxide Gas Sensor 3 Electrode electrochemical For Waste Gas

 

Features:

CiTiceLs may exhibit a response to certain gases in a sample other than the target gas. The table below shows the typical response of 5ND sensors to a number of common cross-interfering gases. The figures are expressed as a percentage of the primary sensitivity (i.e. nitrogen dioxide = 100%). Gas Response Gas Response Hydrogen sulphide: ≈-25% Hydrogen: <-1% Sulphur dioxide: ≈-3% Hydrogen chloride: <-1% Nitric oxide: <1% Carbon monoxide: <-1% ** For details of other possible cross-interfering gases contact City Technology

 

Specifications:

Nominal Range 0-200ppm
Maximum Overload 1000ppm
Expected Operating Life Two years in air
Output Signal 0.37 ± 0.07 μA/ppm
Resolution at 20°C 0.5ppm
Temperature Range -20°C to +50°C

 