Product Details:
|
Maximum Zero Shift: | -1ppm Equivalent | Long Term Output Drift: | <2% Signal Loss/month |
---|---|---|---|
Recommended Load: | 33 Ω | Bias Voltage: | Not Required |
Repeatability: | 2% Of Signal | Output Linearity: | Linear |
Product Description:
5ND Electrochemical NO2 Gas Sensor For Exhaust Gas
Features:
CiTiceLs may exhibit a response to certain gases in a sample other than the target gas. The table below shows the typical response of 5ND sensors to a number of common cross-interfering gases. The figures are expressed as a percentage of the primary sensitivity (i.e. nitrogen dioxide = 100%). Gas Response Gas Response Hydrogen sulphide: ≈-25% Hydrogen: <-1% Sulphur dioxide: ≈-3% Hydrogen chloride: <-1% Nitric oxide: <1% Carbon monoxide: <-1% ** For details of other possible cross-interfering gases contact City Technology
Specifications:
Nominal Range | 0-200ppm |
Maximum Overload | 1000ppm |
Expected Operating Life | Two years in air |
Output Signal | 0.37 ± 0.07 μA/ppm |
Resolution at 20°C | 0.5ppm |
Temperature Range | -20°C to +50°C |
Contact Person: Xu
Tel: 86+13352990255