Product Details:
|
| Operating Temperature Range: | -40±50℃ | Linear Range: | 0-100ppm |
|---|---|---|---|
| Typical Baseline Range (pure Air): | ±1 Ppm N H 3 Equivalent | Repeatability: | ±10% |
| T90 Response Time: | <40 Seconds | Maximum Load: | 200ppm |
| Resolution: | 1ppm | Range: | 0-100ppm |
| Highlight: | 200ppm Gas Sensor,1ppm Resolution Gas Sensor,GS+4NH3-100 Gas Sensor |
||
GS+4NH3-100 Ammonia NH3 Sensor Low Range 4 Series High Stability
The GS+4NH3-100 is an Ammonia (NH3) sensor in a 4-series format with a 3-pin connector. The GS+4NH3-100 requires a 0V bias voltage. The GS+4NH3-100 has a measurement range of 0 - 100 ppm, an output current of 100 ± 30 nA/ppm, a T90 response time of less than 60 seconds, and a 12-month warranty. Key features of the GS+4NH3-100 include: high stability, fast response and recovery, strong environmental stability, and low range (0-100ppm).
Common Applications:
Industrial Safety
General Industrial
Biogas
Food and Beverage
HVAC
Refrigeration
Air Quality
Automotive
| Output signal | 100 ± 30 nA / ppm |
| Typical Baseline Range (pure air) | ±1 ppm NH3 equivalent |
| T90 Response Time | < 60 seconds |
| Measurement Range | 0 - 100 ppm |
| Maximum Overload | 200 ppm |
| Repeatability | ± 5% |
| Recommended Load Resistor | 10 Ohms |
| Resolution (Electronics dependent) | 1ppm |
![]()
Contact Person: Xu
Tel: 86+13352990255