logo
Send Message
  • English
Home ProductsGas Sensor

YJJ Detectable Gas Type Ethylene Oxide Electrochemical Gas Sensor 4ETO AT204-800

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

YJJ Detectable Gas Type Ethylene Oxide Electrochemical Gas Sensor 4ETO AT204-800

YJJ Detectable Gas Type Ethylene Oxide Electrochemical Gas Sensor 4ETO AT204-800
YJJ Detectable Gas Type Ethylene Oxide Electrochemical Gas Sensor 4ETO AT204-800 YJJ Detectable Gas Type Ethylene Oxide Electrochemical Gas Sensor 4ETO AT204-800 YJJ Detectable Gas Type Ethylene Oxide Electrochemical Gas Sensor 4ETO AT204-800 YJJ Detectable Gas Type Ethylene Oxide Electrochemical Gas Sensor 4ETO AT204-800

Large Image :  YJJ Detectable Gas Type Ethylene Oxide Electrochemical Gas Sensor 4ETO AT204-800

Product Details:
Place of Origin: UK
Brand Name: CITY
Model Number: 4ETO AT204-800
Payment & Shipping Terms:
Minimum Order Quantity: 1
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

YJJ Detectable Gas Type Ethylene Oxide Electrochemical Gas Sensor 4ETO AT204-800

Description
Response Time (T90): <120s Detection Gas: Ethylene Oxide (ETO)
Resolution: 0.1ppm Measurement Limit: 100ppm
Bias Voltage: 300mV Range: 0-20ppm
Sensitivity: 1.8±0.3 UA/ppm
Highlight:

Ethylene Oxide Electrochemical Gas Sensor

,

Detectable Ethylene Oxide Gas Sensor

,

4ETO AT204-800 Gas Sensor

Product Description:

The Gas Sensor is equipped with a rapid response time (T90) of less than 120 seconds, ensuring swift and accurate detection of ETO levels in the environment. The sensor operates at a bias voltage of 300mV, optimizing performance and reliability.

With a wide detection range of 0-20ppm, the Gas Sensor offers versatility in monitoring ETO concentrations across various settings. The measurement limit of 100ppm ensures that the sensor can effectively detect elevated levels of ETO, providing timely warnings and ensuring safety.

Whether used in industrial facilities, medical environments, or other applications requiring ETO detection, the Gas Sensor delivers consistent and dependable performance. Its advanced technology and precision make it an invaluable tool for ensuring air quality and safety.

Invest in the Gas Sensor today and experience the benefits of reliable ETO detection with the latest CatEx 125 PR gas sensor. Stay ahead of potential risks and safeguard your surroundings with this state-of-the-art solution.

 

Features:

  • Product Name: Gas Sensor
  • Detection Gas: Ethylene Oxide (ETO)
  • Response Time (T90): <120s
  • Resolution: 0.1ppm
  • Measurement Limit: 100ppm
  • Range: 0-20ppm
  • LEL
  • Expected Sensor Life > 4 years
 

Technical Parameters:

Detection gas Ethylene Oxide (ETO)
Resolution 0.1ppm
Range 0-20ppm
Bias voltage 300mV
Sensitivity 1.8±0.3 UA/ppm
Response time (T90) <120s
Measurement limit 100ppm
 

Applications:

CITY gas sensor model 4ETO AT204-800 is a cutting-edge product designed for precise detection of Ethylene Oxide (ETO) gas in various applications. With a range of 0-20ppm, this sensor offers high sensitivity with a resolution of 0.1ppm, making it ideal for critical environments where ETO monitoring is essential.

Originating from the UK, this advanced sensor from CITY is equipped with state-of-the-art technology that ensures reliable and accurate gas detection. Its response time (T90) of less than 120s enables quick and efficient detection of ETO gas leaks, providing timely alerts to prevent potential hazards.

The CITY 4ETO AT204-800 gas sensor is suitable for a wide range of applications and scenarios. Its versatility makes it a valuable tool in industrial settings, healthcare facilities, laboratories, and other environments where ETO monitoring is crucial for safety and compliance.

Whether used in manufacturing facilities, sterilization units, or research laboratories, this gas sensor offers unparalleled performance and precision. Its sensitivity of 1.8±0.3 UA/ppm ensures accurate detection of ETO gas concentrations, helping to maintain a safe and secure environment.

With the CITY 4ETO AT204-800 gas sensor, customers can benefit from a reliable and innovative solution for ETO gas detection. Its advanced features, including the New, CatEx 125 PR technology, make it a top choice for industries and organizations seeking reliable gas sensing capabilities.

 

Customization:

Customize your gas sensor with CITY's Product Customization Services for the Gas Sensor.

Brand Name: CITY

Model Number: 4ETO AT204-800

Place of Origin: UK

Bias voltage: 300mV

Range: 0-20ppm

Detection gas: Ethylene Oxide (ETO)

Response time (T90): <120s

Sensitivity: 1.8±0.3 UA/ppm

Experience new features and expected sensor life of over 4 years with this gas sensor.

 

Support and Services:

Our Gas Sensor product comes with comprehensive Technical Support and Services to assist you with any issues or questions you may have. Our team of experts is available to provide guidance on installation, troubleshooting, and product usage. Additionally, we offer maintenance services to ensure optimal performance of the Gas Sensor over time. Feel free to reach out to us for any technical assistance you may require.

 

Packing and Shipping:

Product Packaging:

Our Gas Sensor is carefully packaged in a sturdy cardboard box to ensure safe delivery. The sensor is securely cushioned with bubble wrap to prevent any damage during transit.

Shipping:

We offer fast and reliable shipping services for our Gas Sensor product. Orders are typically processed within 1-2 business days and shipped via trusted carriers to ensure timely delivery.

Contact Details
ShenzhenYijiajie Electronic Co., Ltd.

Contact Person: Miss. Xu

Tel: 86+13352990255

Send your inquiry directly to us (0 / 3000)