logo
Send Message
  • English
Home ProductsGas Sensor

3FF 3F/F Carbon Monoxide CO Gas Sensor with Acid Gas Filtering and Accessory Options

I'm Online Chat Now

3FF 3F/F Carbon Monoxide CO Gas Sensor with Acid Gas Filtering and Accessory Options

3FF 3F/F Carbon Monoxide CO Gas Sensor with Acid Gas Filtering and Accessory Options
3FF 3F/F Carbon Monoxide CO Gas Sensor with Acid Gas Filtering and Accessory Options 3FF 3F/F Carbon Monoxide CO Gas Sensor with Acid Gas Filtering and Accessory Options 3FF 3F/F Carbon Monoxide CO Gas Sensor with Acid Gas Filtering and Accessory Options 3FF 3F/F Carbon Monoxide CO Gas Sensor with Acid Gas Filtering and Accessory Options

Large Image :  3FF 3F/F Carbon Monoxide CO Gas Sensor with Acid Gas Filtering and Accessory Options

Product Details:
Place of Origin: UK
Model Number: 3FF 3F/F
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5workingdays
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

3FF 3F/F Carbon Monoxide CO Gas Sensor with Acid Gas Filtering and Accessory Options

Description
Operating Principle: 3-electrode Electrochemical Measurement Range: 0-4000 Ppm CO
Maximum Overload: 20000 Ppm CO Filter: To Remove Acid Gases
Filter Life: 560,000 Ppm Hours Sensitivity*: 0.030 ± 0.006 μA/ppm
Highlight:

Accessories Options Carbon Monoxide CO Gas Sensor

,

3FF 3F/F CO Gas Sensor

,

Acid Gas Filtering CO Gas Sensor

3FF Carbon Monoxide Sensor

 

purpose of this document is to present the performance specification of the 3FF Carbon Monoxide gas sensor.
This document should be used in conjunction with the Operating Principles (OP08) and the Product Safety Datasheet
(PSDS 16).
The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3 months from the date of sensor
manufacture.
Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to
the Operating Principles OP08.

 

CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important
that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments
and operation.
When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is
fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.

 

Resolution 1 ppm CO
Response Time (T90)* <30 seconds
Baseline Offset (clean air) Baseline Offset (clean air)
Zero Shift (+20°C to +40°C) Zero Shift (+20°C to +40°C)
Repeatability 1% of signal

 

3FF 3F/F Carbon Monoxide CO Gas Sensor with Acid Gas Filtering and Accessory Options 0

 

Contact Details
ShenzhenYijiajie Electronic Co., Ltd.

Contact Person: Miss. Xu

Tel: 86+13352990255

Send your inquiry directly to us (0 / 3000)