3HHLM Low Sensitivity Gas Sensor for Methanol and Hydrogen Sulfide H2S Detection 3HHLM Low Sensitivity Gas Sensor for Methanol and Hydrogen Sulfide H2S Detection 3HHLM Low Sensitivity Gas Sensor for Methanol and Hydrogen Sulfide H2S Detection 3HHLM Low Sensitivity Gas Sensor for Methanol and Hydrogen Sulfide H2S Detection

Large Image :  3HHLM Low Sensitivity Gas Sensor for Methanol and Hydrogen Sulfide H2S Detection

Product Details:
Place of Origin: UK
Model Number: 3HHLM
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5workingdays
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

3HHLM Low Sensitivity Gas Sensor for Methanol and Hydrogen Sulfide H2S Detection

Description
Operating Principle: 3-electrode Electrochemical Measurement Range: 0-50 Ppm H2S
Maximum Overload: 500 Ppm H2S Filter: None
Sensitivity*: 1.70 ± 0.30 μA/ppm Response Time (T90)*: Response Time (T90)*
Highlight:

3HHLM Gas Sensor for H2S

,

3HHLM Gas Sensor for Methanol

,

3HHLM Low Sensitivity Gas Sensor

3HHLM Hydrogen Sulfide Sensor

 

The 3HHLM CiTiceL is designed for use in applications where methanol might be present. Whilst cross
sensitivity reactions on CiTiceLs are normally readily defined, the behavior of the 3HHLM when exposed to
methanol is significantly more complex, and can not be specified as above for carbon monoxide. The 3HH/LM
CiTiceL is the result of an extensive development project, which has achieved, for this application, a significant
performance advantage over standard 3HH CiTiceLs

 

CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important
that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments
and operation.
When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is
fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.

 

Baseline Offset (clean air)* Baseline Offset (clean air)*
Maximum Zero Shift 0.1 ppm H2S equivalent
Resolution 0.1 ppm (when used with
recommended electronics)
Repeatability 1% of signal
Recommended Load Resistor 10 Ω

 