Product Details:
|
Product Model: | CLL-6112-300 | Detected Gases: | Most Combustible Gases And Vapors |
---|---|---|---|
Range: | 0-100%LEL | Response Time (T90): | < 20 Seconds (methane) |
Linear: | 0-75%LEL | Long-term Stability: | <±5% Signal Value/month |
Baseline Drift: | <±5%LEL Methane/month | Warranty Period: | 12 Months After Delivery |
Highlight: | 0-100% Combustible gas sensor,Classic Line Combustible gas sensor,3R-2.3V Combustible gas sensor |
CLL-6112-300 Classic Line 3R-2.3V Combustible gas sensor 0-100% 3LEL
Product features:
Excellent impact resistance
Excellent resistance to high concentration methane impact
Excellent long-term stability
Excellent resistance to H2S toxicity
Excellent resistance to HMDS toxicity
Instructions for use:
1. All the above performance specifications are measured at ambient conditions: temperature 20 ℃, relative humidity 50%RH, one atmospheric pressure (100 kPa or ambient pressure).
2. Target gas is recommended for calibration. In the case of calibration with cross-sensitive gases, we do not guarantee the accuracy of calibration and measurement.
3. The cross sensitivity will fluctuate by +/ -30% and may vary with the production batch of the sensor and the life of the sensor.
4. The cross-sensitivity includes but is not limited to the above gases, and the sensor may respond to other gases.
Operating temperature | -20oC to 50oC |
Working humidity | 15-90%RH (non-condensing) |
working voltage | 2.3V D.C |
Working current | 110±10 mA |
Storage environment | No silicon, lead, tin, and sulfur |
Contact Person: Miss. Xu
Tel: 86+13352990255