Product Details:
|
Operating Principle: | 3-electrode Electrochemical | Measurement Range: | 0-1000 Ppm CO |
---|---|---|---|
Maximum Overload: | 2000 Ppm CO | Filter: | To Remove Acid Gases And Hydrocarbons |
Linearity: | Within ±5% | ||
Highlight: | YJJ Carbon Monoxide Gas Sensor,2112B2006 Carbon Monoxide Gas Sensor,4CFC Carbon Monoxide Gas Sensor |
Product Description:
4CFC Carbon Monoxide (CO) Gas Sensor Part Number: 2112B2006
Features:
Nominal Range 0-1000 ppm CO
Maximum Overload 2000 ppm CO
Inboard Filter To remove H2S
Expected Operating Life Two years in air
Output Signal 0.37 ± 0.07 µA/ppm
Resolution 0.5ppm
Temperature Range -20° to +50°C
Pressure Range Atmospheric ± 10%
Pressure Coefficient 0.015 % signal/mBar
T90 Response Time £20 seconds
Relative Humidity Range 15 to 90% non-condensing
Typical Baseline Range -0.25 to +0.5ppm equiv.
(pure air)
Maximum Zero Shift 1ppm equivalent
(+20°C to +40°C)
Long Term Output Drift <2% signal loss/month
Recommended Load 10W
Resistor Not required
Bias Voltage
Repeatability 1% of signal
Output Linearity Linear
Specifications:
Housing Material | Noryl 110 |
Baseline Offset (clean air)* | < ±2 ppm equivalent |
Repeatability | < ±3% |
Weight | 5 g (nominal) |
Contact Person: Miss. Xu
Tel: 86+13352990255