logo
Send Message
  • English
Home ProductsOxygen Gas Sensor

YJJ MOX-3 MOX3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

YJJ MOX-3 MOX3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor

YJJ MOX-3 MOX3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor
YJJ MOX-3 MOX3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor YJJ MOX-3 MOX3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor YJJ MOX-3 MOX3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor YJJ MOX-3 MOX3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor YJJ MOX-3 MOX3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor YJJ MOX-3 MOX3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor

Large Image :  YJJ MOX-3 MOX3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor

Product Details:
Place of Origin: Britain
Brand Name: CITY
Model Number: MOX-3 MOX3 AA829-M10
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: canning
Delivery Time: 3 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 2200

YJJ MOX-3 MOX3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor

Description
Temperature Compensation: <2% O2 Equivalent (0°C To 40°C) External Load Resistor: 10 KΩ Minimum
Housing Material: White ABS Weight: 42 G
Highlight:

Medical Oxygen Battery Oxygen Sensor

,

YJJ MOX-3 Oxygen Sensor

,

MOX3 AA829-M10 Oxygen Sensor

Product Description:

MOX-3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor

 

Features:

The purpose of this document is to present the performance specification of the MOX3 oxygen gas sensor.

This document should be used in conjunction with the Operating Principles (OP04) and the Product Safety Datasheet (PSDS 4).

The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3 months from the date of sensor manufacture.

Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP04).

 

Important Note: Connection should be made via recommended mating parts only. Soldering to the sensor will damage it and invalidate the warranty.

For further information on the external load resistance and connection to the recommended mating part, please see Operating Principle OP-04 or contact City Technology.

All performance data is based on measurements made with cylinder gases using a flow rate of 100 mls/min. Conditions at 20°C, 50% RH and 1013 mBar. For sensor performance data under other conditions, contact City Technology.

Performance characteristics outline the performance of sensors supplied within the first 3 months. Output signal can drift below the lower limit over time.

 

Specifications:

Measurement range 0 mBar to 1500 mBar O2
Response Time (T90) <15 s (air to 100% O2)
Baseline Offset <200 μV
Linearity Linear 0% to 100% O2

 