ME3-NO2 Electrochemical Gas Sensor Detect Gas Concentration By Measuring Current Based On The Electrochemical Principle ME3-NO2 Electrochemical Gas Sensor Detect Gas Concentration By Measuring Current Based On The Electrochemical Principle ME3-NO2 Electrochemical Gas Sensor Detect Gas Concentration By Measuring Current Based On The Electrochemical Principle

Large Image :  ME3-NO2 Electrochemical Gas Sensor Detect Gas Concentration By Measuring Current Based On The Electrochemical Principle

Product Details:
Model Number: ME3-NO2
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5work days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

ME3-NO2 Electrochemical Gas Sensor Detect Gas Concentration By Measuring Current Based On The Electrochemical Principle

Description
Measurement Range: 0~20ppm Max Detecting Concentration: 150ppm
Sensitivity: (0.78±0.42)µA/ppm Resolution Ratio: 0.1ppm
Response Time(T90): <25S Load Resistance(recommended): 10Ω
Highlight:

Current Based Electrochemical Gas Sensor

,

Electrochemical Principle Gas Sensor

ME3-NO2 Electrochemical Gas Sensor Detect Gas Concentration By Measuring Current Based On The Electrochemical Principle

 

ME3-NO2 electrochemical sensor detect gas concentration by measuring current based on the electrochemical principle, which utilizes the electrochemical oxidation process of target gas on the working electrode inside the electrolytic cell, the current produced in electrochemical reaction of the target gas are in direct proportion with its concentration while following Faraday law, then concentration of the gas could be get by measuring value of current.

 

Features :

* Low consumption

* High precision

* High sensitivity

* Wide linear range

* Good anti-interference ability

* Excellent repeatability and stability

 

Application:

Widely used in industrial and environmental protection fields

 

Output Linearity linear
Zero drift(-20℃~40℃) 0.2ppm
Storage temperature 20℃~50℃
Storage Humidity 15﹪~90﹪RH
Pressure range Normal atmosphere ±10%

 