logo
Send Message
  • English
Home ProductsGas Sensor

YJJ AC400-R00A-CIT 1H2S 0.5~200 ppm H2S Analog Gas Sensor Compact Small Size

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

YJJ AC400-R00A-CIT 1H2S 0.5~200 ppm H2S Analog Gas Sensor Compact Small Size

YJJ AC400-R00A-CIT 1H2S 0.5~200 ppm H2S Analog Gas Sensor Compact Small Size
YJJ AC400-R00A-CIT 1H2S 0.5~200 ppm H2S Analog Gas Sensor Compact Small Size YJJ AC400-R00A-CIT 1H2S 0.5~200 ppm H2S Analog Gas Sensor Compact Small Size YJJ AC400-R00A-CIT 1H2S 0.5~200 ppm H2S Analog Gas Sensor Compact Small Size YJJ AC400-R00A-CIT 1H2S 0.5~200 ppm H2S Analog Gas Sensor Compact Small Size YJJ AC400-R00A-CIT 1H2S 0.5~200 ppm H2S Analog Gas Sensor Compact Small Size YJJ AC400-R00A-CIT 1H2S 0.5~200 ppm H2S Analog Gas Sensor Compact Small Size

Large Image :  YJJ AC400-R00A-CIT 1H2S 0.5~200 ppm H2S Analog Gas Sensor Compact Small Size

Product Details:
Place of Origin: Britain
Brand Name: CITY
Model Number: AC400-R00A-CIT 1h2s
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: boxed
Delivery Time: 3 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 2200

YJJ AC400-R00A-CIT 1H2S 0.5~200 ppm H2S Analog Gas Sensor Compact Small Size

Description
Recovery Time* From 200 Ppm To <4 Ppm: < 180 Seconds Baseline Offset* (in Clean Air): < ±0.5 Ppm H2S Equivalent
Baseline Shift -40°C To +60°C: < ±3 Ppm H2S Equivalent Repeatability: < ±5% Of Measured Value
Highlight:

Compact Small Size Gas Sensor

,

0.5~200 ppm Gas Sensor

Product Description:

AC400-R00A-CIT 0.5~200 ppm H2S Analog Gas Sensor Compact Small Size

 

Features:

 

The purpose of this document is to present the performance specification of the 1 Series 1HS hydrogen sulfide gas sensor.

This document should be used in conjunction with the 1HS Characterization Note, the Operating Principles (OP08) and the Product Safety Datasheet (PSDS 12.1).

To the best of City Technology’s knowledge, the data provided in this document is more suitable when the sensor is used at 20°C, 50% rH and 1013 mBar for 3 months from the date of sensor manufacture. For guidance on sensor performance outside of these limits, please refer to the 1HS Characterization Note.

Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP08).

 

Specifications:

Technology

 

Electrochemical

 

Onboard Filter

 

None

 

Range

0.5 to 200 ppm H2S

 

T90 Response Time

Typically < 30 seconds

 

 

YJJ AC400-R00A-CIT 1H2S 0.5~200 ppm H2S Analog Gas Sensor Compact Small Size 0

 

Contact Details
ShenzhenYijiajie Electronic Co., Ltd.

Contact Person: Miss. Xu

Tel: 86+13352990255