logo
Send Message
  • English
Home ProductsGas Sensor

NH3/SR-1000 NH3/SR-200 NH3/SR-1000-S 3-Electrode Ammonia Gas Sensor Electrochemical Gas Sensor Leak Detection Discontinuous Measurement Safety And Environmental Control

I'm Online Chat Now

NH3/SR-1000 NH3/SR-200 NH3/SR-1000-S 3-Electrode Ammonia Gas Sensor Electrochemical Gas Sensor Leak Detection Discontinuous Measurement Safety And Environmental Control

NH3/SR-1000 NH3/SR-200 NH3/SR-1000-S 3-Electrode Ammonia Gas Sensor Electrochemical Gas Sensor Leak Detection Discontinuous Measurement  Safety And Environmental Control
NH3/SR-1000 NH3/SR-200 NH3/SR-1000-S 3-Electrode Ammonia Gas Sensor Electrochemical Gas Sensor Leak Detection Discontinuous Measurement  Safety And Environmental Control NH3/SR-1000 NH3/SR-200 NH3/SR-1000-S 3-Electrode Ammonia Gas Sensor Electrochemical Gas Sensor Leak Detection Discontinuous Measurement  Safety And Environmental Control NH3/SR-1000 NH3/SR-200 NH3/SR-1000-S 3-Electrode Ammonia Gas Sensor Electrochemical Gas Sensor Leak Detection Discontinuous Measurement  Safety And Environmental Control NH3/SR-1000 NH3/SR-200 NH3/SR-1000-S 3-Electrode Ammonia Gas Sensor Electrochemical Gas Sensor Leak Detection Discontinuous Measurement  Safety And Environmental Control

Large Image :  NH3/SR-1000 NH3/SR-200 NH3/SR-1000-S 3-Electrode Ammonia Gas Sensor Electrochemical Gas Sensor Leak Detection Discontinuous Measurement Safety And Environmental Control

Product Details:
Model Number: NH3/SR-1000 NH3/SR-200 NH3/SR-1000-S
Payment & Shipping Terms:
Minimum Order Quantity: 1
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

NH3/SR-1000 NH3/SR-200 NH3/SR-1000-S 3-Electrode Ammonia Gas Sensor Electrochemical Gas Sensor Leak Detection Discontinuous Measurement Safety And Environmental Control

Description
Operation Principle: 3-Electrode Electrochemical Nominal Range: 0 - 1000 Ppm
Maximum Overload: 2000 Ppm Output Signal: 25 ± 8 NA/ppm
Resolution (Electronics Dependent): < 2.0 Ppm T90 Response Time: < 50 S
Typical Baseline Range (pure Air, 20°C): -16 Ppm To 16 Ppm Maximum Zero Shift (+20°C To +40°C): -32 Ppm
Highlight:

Leak Detection Gas Sensor

                                                     Ammonia Gas Sensor NH3/SR-1000

                                                     NH3 Gas Sensor in Standard Housing

 

Applications:

• Leak Detection

• Discontinuous Measurement

• Safety and Environmental Control

 

Rec. Load Resistor 10 - 33 Ω
Bias (V_Sens-V_Ref) not allowed
Conformity to RoHS directive RoHS Compliance
Relative Humidity Range 15 % to 90 % RH non-condensing
Temperature Range -10 °C to 50 °C
Pressure Range Atmospheric ± 10%
Pressure Coefficient N.D.
Humidity Effect 1) < 4 ppm

 