logo
  • English
Home ProductsOxygen Gas Sensor

Gas Oxygen Sensor SGX-VOX Electrochemical Gas Sensor 0-100% Oxygen (O2) Sensor With On Board Temperature Compensation For Ventilators

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

Gas Oxygen Sensor SGX-VOX Electrochemical Gas Sensor 0-100% Oxygen (O2) Sensor With On Board Temperature Compensation For Ventilators

Gas Oxygen Sensor SGX-VOX Electrochemical Gas Sensor 0-100% Oxygen (O2) Sensor With On Board Temperature Compensation For Ventilators
Gas Oxygen Sensor SGX-VOX Electrochemical Gas Sensor 0-100% Oxygen (O2) Sensor With On Board Temperature Compensation For Ventilators Gas Oxygen Sensor SGX-VOX Electrochemical Gas Sensor 0-100% Oxygen (O2) Sensor With On Board Temperature Compensation For Ventilators Gas Oxygen Sensor SGX-VOX Electrochemical Gas Sensor 0-100% Oxygen (O2) Sensor With On Board Temperature Compensation For Ventilators Gas Oxygen Sensor SGX-VOX Electrochemical Gas Sensor 0-100% Oxygen (O2) Sensor With On Board Temperature Compensation For Ventilators Gas Oxygen Sensor SGX-VOX Electrochemical Gas Sensor 0-100% Oxygen (O2) Sensor With On Board Temperature Compensation For Ventilators

Large Image :  Gas Oxygen Sensor SGX-VOX Electrochemical Gas Sensor 0-100% Oxygen (O2) Sensor With On Board Temperature Compensation For Ventilators

Product Details:
Model Number: SGX-VOX
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5work days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

Gas Oxygen Sensor SGX-VOX Electrochemical Gas Sensor 0-100% Oxygen (O2) Sensor With On Board Temperature Compensation For Ventilators

Description
Output Signal: 9-13mV In Air* Zero Current (offset): <0.1% O2
T90 Response Time: < 5 Seconds T99.5 Response Time: <50 Sec
Measurement Range: 0-100% O2 Linearity: Linear
Highlight:

Ventilators Oxygen Gas Sensor

Gas Oxygen Sensor SGX-VOX Electrochemical Gas Sensor 0-100% Oxygen (O2) Sensor With On Board Temperature Compensation For Ventilators

 

CROSS - SENSITIVITY:

DATA Toxic gases at TLV levels will have no cross-sensitivity effect on SGX-VOX oxygen sensors. At very high levels (i.e. % levels), highly oxidising gases (e.g. ozone, chlorine) will interfere to the extent of their oxygen equivalent, but most other commonly occurring gases will have no effect.

 

ACID GASES :

Acid gases such as CO2 and SO2 will be absorbed by the electrolyte and tend to increase the flux of oxygen to the electrode. This gives an enhanced oxygen signal of approximately 0.3% of signal per 1% CO2. SGX-VOX sensor is not suitable for continuous operation in concentrations of CO2 above 25%. The SGX-VOX sensor is not designed for use in applications where anaesthetic gases are present.

 

Temperature Range -20°C to +50°C
Pressure Range 500 to 2000 mbar
Operating Humidity Range 0% to 99% RH (non condensing)
Long Term Output Drift <5% per annum
Recommended Storage Temp 0°C to 20°C

 

Gas Oxygen Sensor SGX-VOX Electrochemical Gas Sensor 0-100% Oxygen (O2) Sensor With On Board Temperature Compensation For Ventilators 0

Contact Details
ShenzhenYijiajie Electronic Co., Ltd.

Contact Person: Miss. Xu

Tel: 86+13352990255

Send your inquiry directly to us (0 / 3000)