logo
Send Message
  • English
Home ProductsOxygen Gas Sensor

YJJ AO-06 Electrochemical Oxygen Sensor And Oxygen Battery Can Be Used In Oxygen Generator Control Equipment To Replace MOX-4 And MOX4

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

YJJ AO-06 Electrochemical Oxygen Sensor And Oxygen Battery Can Be Used In Oxygen Generator Control Equipment To Replace MOX-4 And MOX4

YJJ AO-06 Electrochemical Oxygen Sensor And Oxygen Battery Can Be Used In Oxygen Generator Control Equipment To Replace MOX-4 And MOX4
YJJ AO-06 Electrochemical Oxygen Sensor And Oxygen Battery Can Be Used In Oxygen Generator Control Equipment To Replace MOX-4 And MOX4 YJJ AO-06 Electrochemical Oxygen Sensor And Oxygen Battery Can Be Used In Oxygen Generator Control Equipment To Replace MOX-4 And MOX4 YJJ AO-06 Electrochemical Oxygen Sensor And Oxygen Battery Can Be Used In Oxygen Generator Control Equipment To Replace MOX-4 And MOX4

Large Image :  YJJ AO-06 Electrochemical Oxygen Sensor And Oxygen Battery Can Be Used In Oxygen Generator Control Equipment To Replace MOX-4 And MOX4

Product Details:
Place of Origin: CHINA
Brand Name: YJJ
Model Number: AO-06
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: canning
Delivery Time: 3 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 2200

YJJ AO-06 Electrochemical Oxygen Sensor And Oxygen Battery Can Be Used In Oxygen Generator Control Equipment To Replace MOX-4 And MOX4

Description
Output Voltage: 9-13 MV (in Air) Measurement Range: 0-100%
Temperature Compensation: < 2% O² Response Time (T90): < 15 Seconds
Highlight:

MOX-4 Oxygen Sensor

,

Oxygen Generator Control Equipment Oxygen Sensor

,

AO-06 Electrochemical Oxygen Sensor

Product Description:

AO-06 Electrochemical Oxygen Sensor And Oxygen Battery Can Be Used In Oxygen Generator Control Equipment To Replace MOX-4 And MOX4

 

https://mao.ecer.com/test/oxygengassensors.com/sale-52171498-yjj-mox4-mox-4-aa829-m20-oxygen-sensor-with-threaded-connector-for-medical-oxygen-battery.html

 

Features:

I. Product Overview

The AO-06 oxygen sensor is an electrochemical sensor specifically designed for measuring oxygen concentration in medical equipment. Its interface model is 5520257-2. It adopts a molded main body design and features rapid response and long service life. It can be replaced domestically, providing customers with excellent quality while reducing costs. The difference between this sensor and the AO-07 oxygen sensor lies in the different pin definitions.


Ii. Application
The AO-06 oxygen sensor does not require an external power supply when in operation. It has undergone professional and accurate product calibration and temperature compensation before leaving the factory. It can be used as the sensing component of oxygen analyzers, such as oxygen generator control devices, medical ventilators, anesthesia equipment, incubators, etc.


Iii. Product Features

. Full-range linear output
. No external power supply is required for operation
. Temperature compensation
"Quick response"
Accurate and reliable
. Strong anti-interference ability
Technical parameters
Output voltage: 9-13 mV (in air)
Measurement range: 0-100%
Temperature compensation < 2% O² equivalent (0℃-40℃)
Response time (T90) < 15 seconds
Working temperature range
0℃ to +50℃


Range of working pressure
0.5 Bar - 2.0 Bar
Operating humidity range: 0% - 99%RH (no condensation)

 

 

Shenzhen Yijiajie Electronic Technology Co., Ltd. mainly serves OEM manufacturers in the sales of sensor products. In the field of sensing and control products, we provide product sales and technical support services in China for globally renowned manufacturers. We are also currently a professional supplier of sensing and control products in China and Hong Kong. The head office was founded in Hong Kong in 2002. The Shenzhen company is located at the intersection of Shennan Middle Road and Huaqiang North Road in Shenzhen. Meanwhile, the company has a large amount of spot inventory in Shenzhen and Hong Kong and can place orders directly from abroad with prompt delivery. We hope to cooperate with domestic related manufacturers to provide your company with high-quality and satisfactory products and make your products more competitive. We sincerely look forward to cooperating with you.

 

Specifications:

Response time (T90) <15 seconds
Working pressure range 0.5-2.0bar
Shell material White ABS
Long-term drift 99%RH(no condensation)

 

YJJ AO-06 Electrochemical Oxygen Sensor And Oxygen Battery Can Be Used In Oxygen Generator Control Equipment To Replace MOX-4 And MOX4 0YJJ AO-06 Electrochemical Oxygen Sensor And Oxygen Battery Can Be Used In Oxygen Generator Control Equipment To Replace MOX-4 And MOX4 1YJJ AO-06 Electrochemical Oxygen Sensor And Oxygen Battery Can Be Used In Oxygen Generator Control Equipment To Replace MOX-4 And MOX4 2