Product Details:
|
Sensitivity Range: | 3-8 NA/ Mg | Zero Current At: | 20°C < ± 4 NA |
---|---|---|---|
Resolution At: | 20°C < 0.5 Mg/m-3 | Bias Potential: | Not Required |
Highlight: | Amperometric Mercaptan Sensor,2 Electrode Mercaptan Sensor,TBM 2E 50 Mercaptan Sensor |
TBM 2E 50 2441-021-07079 Mercaptane Sensoric Amperometric 2 Electrode High Selectivitiy
FEATURES
Amperometric 2 electrode sensor cell
High selectivitiy
High reliability
Good long term stability
TYPICAL APPLICATIONS
Monitoring of odorants in natural gas applications
Response Time at 20°C | t50 < 40 s calculated from 4 min. exposure time t90 < 90 s calculated from 4 min. exposure time |
Long Term Sensitivity Drift | < 10% per 10 month |
Temperature Range | -10°C to +40°C |
Humidity Range | 10–95% r.H., non–condensing |
Effect of Humidity | No effect |
Sensor Life Expectancy | > 12 months |
Warranty | 9 months |