logo
Send Message
  • English
Home ProductsOxygen Gas Sensor

YJJ PSR-11-917-M Oxygen Sensor And Oxygen Battery Are Used In 760/840 Ventilators

I'm Online Chat Now

YJJ PSR-11-917-M Oxygen Sensor And Oxygen Battery Are Used In 760/840 Ventilators

YJJ PSR-11-917-M Oxygen Sensor And Oxygen Battery Are Used In 760/840 Ventilators
YJJ PSR-11-917-M Oxygen Sensor And Oxygen Battery Are Used In 760/840 Ventilators YJJ PSR-11-917-M Oxygen Sensor And Oxygen Battery Are Used In 760/840 Ventilators YJJ PSR-11-917-M Oxygen Sensor And Oxygen Battery Are Used In 760/840 Ventilators YJJ PSR-11-917-M Oxygen Sensor And Oxygen Battery Are Used In 760/840 Ventilators YJJ PSR-11-917-M Oxygen Sensor And Oxygen Battery Are Used In 760/840 Ventilators YJJ PSR-11-917-M Oxygen Sensor And Oxygen Battery Are Used In 760/840 Ventilators

Large Image :  YJJ PSR-11-917-M Oxygen Sensor And Oxygen Battery Are Used In 760/840 Ventilators

Product Details:
Place of Origin: USA
Brand Name: ALL
Model Number: PSR11-917-M
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Box pack
Delivery Time: 5-8 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 2200

YJJ PSR-11-917-M Oxygen Sensor And Oxygen Battery Are Used In 760/840 Ventilators

Description
Measurement Range: 0- 100% Working Life: 900,000% Hours
Output: 10 To 16 MV Zero-point Voltage: Less Than 0.5 Mv
Resolution: ± 0.1% Response Time: 1MΩ
Highlight:

760/840 Ventilators Oxygen Sensor

,

YJJ PSR-11-917-M Oxygen Battery

,

YJJ PSR-11-917-M Oxygen Sensor

Product Description:

PSR-11-917-M Oxygen Sensor And Oxygen Battery Are Used In 760/840 Ventilators

 

Features:

American AII PSR-11-917-M oxygen sensor PSR-11-917-M oxygen battery

American AII oxygen battery PSR-11-75-KE4, American AII PSR-11-75-KE4 oxygen sensor

American AII oxygen sensor PSR-11-917-M2OEM device:

 

Lead 760 ventilator

 

Lead 840 ventilator

Conditions of the American AII oxygen sensor PSR-11-917-M2:

 

The specification verification pursues improvement changes in the design without further notice. American AII oxygen sensor PSR-11-917-M2

 

At constant temperature and pressure.

2) In air (20.9% oxygen) at 25 ° C and 1 atmosphere pressure.

3) The sensor can store up to 55 ° C intermittent, for example, operating atmospheric pressure.

5) Under normal working conditions, the sensor is necessary to be free from material and process defects within *** time, providing suitable sensor installation and operation.

Measurement range: 0- 100%

 

Working life: 900,000% hours, approximately 5 years in the atmosphere

 

Output: 10 to 16 mV

 

Zero-point voltage: less than 0.5 mv

 

Resolution :± 0.1%

 

Temperature range: 5℃ to 45℃

Pressure range: 0.5 to 1.5 ATM

 

Response time: 1MΩ

 

Accuracy: ±1% (at normal temperature and pressure), ±2% (throughout the full temperature range)

 

Storage temperature: 15℃ to 50℃

 

Sampling port: M16X1 thread

 

Storage life: 6 months (in container)

 

Shelf life: 18 months from the date of shipment

 

Features of the American AII PSR-11-75-KE4 oxygen sensor:

 

The American AII PSR-11-917-M2 is applicable to ventilators such as PB840, 760 Hamilton, and Tianma

 

Oxygen battery for the American AII PSR-11-75-KE6 SLE 2000 ventilator

 

American AII PSR-11-915-4 Oxygen battery Ohmeda 7900 Oxygen battery 6050-004-110 Ohmeda 7100 Oxygen battery 6050-004-110 Ohmeda Aestiva 3000

 

56050-004-110 is compatible with Envite (Anvite). OOM110 is compatible with the M-10 of IT companies, the oxygen battery of Omeda 7100 anesthesia machine, and the oxygen battery of Omeda 7900 anesthesia machine

 

American AII PSR-11-917-J oxygen battery PB7200 ventilator oxygen battery Wuxi Zhongyuan Anesthesia machine oxygen battery Tianma Anesthesia machine oxygen battery

 

American AII PSR-11-75-KE4 oxygen battery, Viasys Vela bird, VELA oxygen battery, VELA ventilator, oxygen sensor

 

American AII PSR-11-75-KE9 oxygen battery, Newport e360, Newport e500, Newport E360 ventilator, oxygen battery, Newport E500 ventilator

 

Specifications:

Recommended load ≥10Ω
Preheating time <30 minutes, after replacing the sensor
Operating temperature 0℃ to 40℃
Pressure range 750 to 1250 hPa

YJJ PSR-11-917-M Oxygen Sensor And Oxygen Battery Are Used In 760/840 Ventilators 0YJJ PSR-11-917-M Oxygen Sensor And Oxygen Battery Are Used In 760/840 Ventilators 1YJJ PSR-11-917-M Oxygen Sensor And Oxygen Battery Are Used In 760/840 Ventilators 2