Product Details:
|
Working Principle: | Partial Pressure Electrochemistry | Output Voltage: | 9-13 MV (in Air) |
---|---|---|---|
Measurement Range: | 0 To 100% | Response Time (T90): | < 15 Seconds |
Accuracy: | ± 1% | Temperature Compensation: | < 2% O2 Equivalent (0-40 ℃) |
Highlight: | 15 seconds Oxygen Gas Sensor,9-13 mV Oxygen Gas Sensor,Quick Response Time Oxygen Gas Sensor |
AO-08 Oxygen Gas Sensor
Product Review:
The AO-08 oxygen sensor is an electrochemical sensor specifically designed for measuring oxygen concentration in medical equipment. It adopts a molded body design and features rapid response and a long service life.
Full-range linear output
The operation does not require an external power supply
Temperature compensation
Quick response
Accurate and reliable
Strong anti-interference ability
Application scope:
The AO-08 oxygen sensor does not require an external power supply when in operation. It has all undergone professional and accurate product calibration and temperature compensation before leaving the factory Sensing components for oxygen analyzers, such as oxygen generator control devices, medical ventilators, anesthesia equipment, incubators, etc.
Installation requirements:
When installing the sensor, it should be tightened by hand and ensure good air tightness. Do not use wrenches or similar mechanical auxiliary tools to prevent The thread of the stop sensor was damaged due to excessive force.
Storage and Usage:
The AO-08 oxygen sensor should avoid exposure to high concentrations of organic solvent vapors during storage, installation and operation. When using sensors with printed circuit boards (PCBS), the PCB should be cleaned with a degreaser before installing the sensor to prevent rosin
Wait for the flux impurities to evaporate and condense, blocking the breathable membrane of the oxygen sensor. Organic solvents are prohibited on the sensor housing as they may cause the plastic to crack.
If the sensor housing is contaminated, the sensor can be cleaned with distilled water and allowed to dry naturally. It is not allowed to use the sensor Sterilize with steam or expose the sensor to an environment containing chemicals such as ethylene oxide and hydrogen peroxide for a long time.
Temperature compensation | < 2% O2 equivalent (0-40 ℃) |
Load resistance | ≥10 kΩ |
Interface | 3.5mm TRS interface |
Shell material | White ABS |
Weight | Approximately 40 grams |
Operating temperature range | 0 to 50 ℃ |
Working pressure range | 0.5-2.0 Bar |
Output voltage | 9-13 mV (in air) |
Measurement range | 0 to 100% |
Response time (T90) | < 15 seconds |
Accuracy | ± 1% |