logo
  • English
Home ProductsGas Sensor

YJJ 4O2-LF 053-0000-000 4 Series Electrochemical Hydrogen Cyanide Sensor Is Used In Field Of Industrial Safety

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

YJJ 4O2-LF 053-0000-000 4 Series Electrochemical Hydrogen Cyanide Sensor Is Used In Field Of Industrial Safety

YJJ 4O2-LF 053-0000-000 4 Series Electrochemical Hydrogen Cyanide Sensor Is Used In Field Of Industrial Safety
YJJ 4O2-LF 053-0000-000 4 Series Electrochemical Hydrogen Cyanide Sensor Is Used In Field Of Industrial Safety YJJ 4O2-LF 053-0000-000 4 Series Electrochemical Hydrogen Cyanide Sensor Is Used In Field Of Industrial Safety

Large Image :  YJJ 4O2-LF 053-0000-000 4 Series Electrochemical Hydrogen Cyanide Sensor Is Used In Field Of Industrial Safety

Product Details:
Place of Origin: USA
Brand Name: YJJ
Model Number: 4O2-LF 053-0000-000
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Box pack
Delivery Time: 5 to 8 working days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 22000

YJJ 4O2-LF 053-0000-000 4 Series Electrochemical Hydrogen Cyanide Sensor Is Used In Field Of Industrial Safety

Description
Range: 0-25% Vol Oxygen Maximum Load: 30% Vol Oxygen
Output Signal (20℃): -100 ± 20 μA (in Air) Response Time (T90): ≤ 15 Seconds
Baseline (20℃): ±0.5% Vol Oxygen Resolution: 0.1% Vol Oxygen
Highlight:

4O2-LF electrochemical hydrogen cyanide sensor

,

Electrochemical hydrogen cyanide sensor

,

053-0000-000 electrochemical hydrogen cyanide sensor

Product Description:

4O2-LF 053-0000-000 4 Series Electrochemical Hydrogen Cyanide Sensor Is Used In Field Of Industrial Safety

 

Features:

Product Description

 

This sensor is lead-free and is used to measure the concentration of oxygen gas. It can be replaced by the standard four-series oxygen electrochemical sensor through pins.

Performance parameters

Range: 0-25% vol oxygen

Maximum load: 30% vol oxygen

Output signal (20℃) -100 ± 20 μA (in air)

The response time (T90) is ≤ 15 seconds

Baseline (20℃) ±0.5% vol oxygen

Resolution: 0.1% vol oxygen

Linearity S=K loge(1/1-C)

Bias voltage -600 mV

Repeatability < 1%

Working environment

Temperature range: -40℃ to 50℃

The pressure range is 1 ± 0.1 standard atmosphere

Humidity range: 15% to 90%RH (no condensation)

Lifespan

Long-term stability < 5% signal value per year

Storage temperature: 10℃ to 30℃

Service life: 5 years (in the air)

Storage time: 12 months (in dedicated packaging boxes)

The warranty period is 36 months

Physical properties

Shell material: ABS

Weight: 5 grams

No directionality

The RoHS compliance has been certified as lead-free

 

Specifications:

Temperature range -40℃ to 50℃
Humidity range 15% to 90%RH
Long-term stability < 5% signal value per year
Storage temperature 10℃ to 30℃
Service life 5 years
Weight 5 grams

 

YJJ 4O2-LF 053-0000-000 4 Series Electrochemical Hydrogen Cyanide Sensor Is Used In Field Of Industrial Safety 0