Product Details:
|
Typical Gas Sensitivity: | 8±4 NA/ppm (at 20°C) | Response Time (T90): | < 120 Seconds |
---|---|---|---|
Daily Repeatability: | < ±10% | Annual Zero Drift: | < 50 Ppm NH₃ |
Long-term Sensitivity Decay: | < 2%/month | Expected Service Life: | 24 Months |
Highlight: | NE4 Electrochemical Gas Sensor,Industrial NH3 Electrochemical Gas Sensor |
NE4-NH3-1000 Electrochemical Gas Sensor
1. Detection Principle:
It belongs to an electrochemical gas sensor, composed of a sensing electrode, counter electrode, and reference electrode. Ammonia gas diffuses into the working electrode through the sensor's diaphragm, where it decomposes and is partially oxidized. Nitrogen is generated at the working electrode, and the resulting protons enter the counter electrode, reacting with dissolved oxygen in the electrolyte to form water. The concentration of ammonia gas is proportional to the current generated by the continuous reaction.
2. Characteristics:
3. Detected Gas:
Ammonia (NH₃).
4. Applications:
5. Electrical Characteristics:
6. Cross Sensitivity:
7. Durability:
Detected Gas | Ammonia (NH₃) |
Measurement Range | 0 - 1000 ppm |
Overload Resistance | 1500 ppm |
Resolution | 5 ppm |
Response Time (T90) | < 120 seconds |
Operating Temperature | -40°C to +50°C |
Operating Humidity | 15% - 90% RH (non-condensing) |
Storage Temperature | -20°C to +50°C |
Service Life | 24 months |
Contact Person: Miss. Xu
Tel: 86+13352990255