Product Details:
|
Nominal Range: | 0 ~ 500 Ppm | Maximum Overload: | 1000 Ppm |
---|---|---|---|
Sensitivity (20℃): | 0.035 ± 0.015 μA/ppm | Response Time (T90): | ≤ 55 S |
Zero Signal (20℃): | < ± 0.2 μA | Baseline Shift (-40℃ ~ 50℃): | < 5 Ppm |
Highlight: | ammonia gas sensor 500S,7NH3 ammonia gas detector,ammonia concentration measurement sensor |
7NH3-500S Ammonia Gas Sensor For Measuring Concentration OfAmmonia Gas
The 7NH3 - 500S gas sensor is mainly used for measuring the concentration of ammonia gas. It is designed for specific instruments to ensure personal safety, and can be applied to occasions where ammonia concentration needs to be monitored, such as ammonia - containing industrial production processes, livestock and poultry breeding places with ammonia emissions, and environments using ammonia - based cleaning products.
Nominal Range | 0 ~ 500 ppm |
Maximum Overload | 1,000 ppm |
Sensitivity (20℃) | 0.035 ± 0.015 μA/ppm |
Response Time (T90) | ≤ 55 s |
Zero Signal (20℃) | < ± 0.2 μA |
Baseline Shift (-40℃ ~ 50℃) | < 3 ppm |
Resolution | 1 ppm |
Bias Voltage | 0 mV |
Temperature Range | -40℃ ~ 50℃ |
Pressure Range | 1 ± 0.1 atm |
Humidity Range | 15% ~ 90%RH (Non - condensing) |
Long - term Output Drift | < 2% signal/month |
Recommended Storage Temperature | 10℃ ~ 30℃ |
Expected Operating Life | 2 years (in clean air) |
Storage Life | 6 months (in original packaging) |
Warranty | 12 months |
Max. Current at 1,000 ppm NH3 | < 0.2 mA |
Max. Open - circuit Voltage | 1.3 V |
Max. Short - circuit Current | < 1.0 A |
Housing Material | ABS |
Weight | 8 g |
Contact Person: Miss. Xu
Tel: 86+13352990255