logo
Home ProductsGas Sensor

H2/C-5000 3-Electrode Electrochemical Hydrogen Gas Sensor for Safety and Process Control

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

H2/C-5000 3-Electrode Electrochemical Hydrogen Gas Sensor for Safety and Process Control

H2/C-5000 3-Electrode Electrochemical Hydrogen Gas Sensor for Safety and Process Control
H2/C-5000 3-Electrode Electrochemical Hydrogen Gas Sensor for Safety and Process Control

Large Image :  H2/C-5000 3-Electrode Electrochemical Hydrogen Gas Sensor for Safety and Process Control

Product Details:
Place of Origin: Switzerland
Model Number: H2/C-5000
Payment & Shipping Terms:
Minimum Order Quantity: 1PCS
Price: Negotiable
Packaging Details: Standard packaging
Delivery Time: 5-8 work days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 5000PCS

H2/C-5000 3-Electrode Electrochemical Hydrogen Gas Sensor for Safety and Process Control

Description
Nominal Range: 0 - 5000 Ppm Maximum Overload: 10000 Ppm
Output Signal: 9.5 ± 2.5 NA/ppm Resolution (Electronics Dependent): < 5.3 Ppm
T90 Response Time: < 45 S Typical Baseline Range (pure Air, 20°C): -40 Ppm To 30 Ppm
Highlight:

hydrogen gas safety sensor

,

3-electrode electrochemical gas sensor

,

process control hydrogen detector

 

                 H2/C-5000 3-Electrode Electrochemical Hydrogen Gas Sensor for Safety and Process Control

 

 

Applications:

 

• Safety and Process Control

 

Important Application Notes:

 

H2 sensors lose >10% of their initial sensitivity within the first month after production before the output stabilizes.

 

 

Rec. Load Resistor 10 - 33 Ω
Bias (V_Sens-V_Ref) not recommended
Conformity to RoHS directive RoHS Compliance
Relative Humidity Range 15 % to 90 % RH non-condensing
Temperature Range -40 °C to 50 °C
Pressure Range Atmospheric ± 10%
Pressure Coefficient N.D.
Humidity Effect None
Expected Operation Life 2 years in air
Expected Long Term Output Drift in air < 2 % signal loss per month after stabilization
Filter Life 6 months in container
Rec. Storage Temperature 5°C - 20°C
Warranty Period 12 months from date of dispatch

 