YJJ C/NLH CNLH Trace Oxygen Sensor 0-1000 PPM AA015-000 Is Used For Trace Oxygen Detection In Glove Boxes

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

YJJ C/NLH CNLH Trace Oxygen Sensor 0-1000 PPM AA015-000 Is Used For Trace Oxygen Detection In Glove Boxes

YJJ C/NLH CNLH Trace Oxygen Sensor 0-1000 PPM AA015-000 Is Used For Trace Oxygen Detection In Glove Boxes
YJJ C/NLH CNLH Trace Oxygen Sensor 0-1000 PPM AA015-000 Is Used For Trace Oxygen Detection In Glove Boxes YJJ C/NLH CNLH Trace Oxygen Sensor 0-1000 PPM AA015-000 Is Used For Trace Oxygen Detection In Glove Boxes YJJ C/NLH CNLH Trace Oxygen Sensor 0-1000 PPM AA015-000 Is Used For Trace Oxygen Detection In Glove Boxes YJJ C/NLH CNLH Trace Oxygen Sensor 0-1000 PPM AA015-000 Is Used For Trace Oxygen Detection In Glove Boxes YJJ C/NLH CNLH Trace Oxygen Sensor 0-1000 PPM AA015-000 Is Used For Trace Oxygen Detection In Glove Boxes

Large Image :  YJJ C/NLH CNLH Trace Oxygen Sensor 0-1000 PPM AA015-000 Is Used For Trace Oxygen Detection In Glove Boxes

Product Details:
Place of Origin: CHINA
Brand Name: YJJ
Model Number: CNLH AA015-000
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Canned
Delivery Time: 5 to 8 working days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 1500

YJJ C/NLH CNLH Trace Oxygen Sensor 0-1000 PPM AA015-000 Is Used For Trace Oxygen Detection In Glove Boxes

Description
Measurement Range: 0-2 Ppm O2 Maximum Overload: 1000 Ppm O2
Filter: None Output Signal: 13 - 17 MV In Air With A 10Ω
Response Time (T95): < 20 Seconds Purge Time: < 6 Hours
Highlight:

trace oxygen sensor for glove boxes

,

CNLH oxygen sensor 0-1000 PPM

,

YJJ gas sensor with warranty

Product Description:

YJJ C/NLH CNLH Trace Oxygen Sensor 0-1000 PPM AA015-000 Is Used For Trace Oxygen Detection In Glove Boxes

 

Features:

CITIPEL Sensor product introduction
The service life of the C/NLL Oxygen CiTiceL is inversely proportional to the amount of oxygen consumed by the sensor. Because City Technology does not have knowledge of the operating conditions of any particular application, the company cannot provide any guarantees about the service life of the sensors. However, the following guidelines should be used:
Under normal operating conditions (i.e. ppm level), the sensor has a large excess capacity and will only gradually lose sensitivity. However, it is recommended to replace the sensor annually to maintain the best sensitivity.
It is recommended not to use these sensors in ambient air, or to keep them in the air for long periods of time. This will greatly reduce the service life of the sensor.

2-electrode electrochemical
0-2 ppm O,
1000 ppm O.
Operating Principle
Measurement Range
Maximum Overload
Filter
Qutput Signa!
None
13 _17 mV in air with a 100
load resistor
< 20 seconds
< 6 hours
Response Time (T.)
Purge Time:
(Ambient air to <10 ppm)
Linearity Linear
ELECTRICAL
Recommended Load Resistor 10 Ω
MECHANICAL
Weight |32 g
Housing Material:
Nickel plated steel
Body
Current Collectors Nickel
Orientation Sensitivity None
ENVIRONMENTAL
Operating Temperature Range -20'C to +50°C
Temperature Coefficient
0.2% signal/°C
Recommended Storage Temp
0'C to 20°C
Atmospheric±10%
Operating Pressure Range
Operating Humidity Range
0-99% RH non-condensing
LIFETIME
Long Term Output Drift
Expected Operating Life
Storage Life
<5% signal losslyear
See below
6 months in CTL container

 

Specifications:

Orientation Sensitivity None
Current Collectors Nickel
Body Nickel plated steel
Weight 32 g

YJJ C/NLH CNLH Trace Oxygen Sensor 0-1000 PPM AA015-000 Is Used For Trace Oxygen Detection In Glove Boxes 0