logo
Home ProductsGas Sensor

YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices

YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices
YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices

Large Image :  YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices

Product Details:
Place of Origin: CHINA
Brand Name: YJJ
Model Number: 7C2H5OH-100
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Canned
Delivery Time: 5 to 8 working days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 1500

YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices

Description
Pressure Factor: < 0.02% Signal /MBar Temperature: -20℃ ~ +50℃
Repeatability: 1% Output Signal Baseline Extent: <±0.4μA
Long Term Drift: < 5% Signal Loss / Year Load Resistance: 10Ω
Highlight:

MST electrochemical ethanol sensor

,

gas leakage alarm sensor

,

7 series ethanol gas sensor

Product Description:

YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices

 

Features:

Reproducibility: 1% output signal

Operating temperature range: Linear, regression coefficient R = 0.999

Operating humidity range: 20°C to 50°C

Operating pressure range: 15% to 90% 6MH (no condensation)

Pressure coefficient: Atmospheric pressure ± 10%

Baseline range: < 0.02% signal/mBar

Long-term drift: < ±0.4 mA

Offset voltage: +300 mV (Note: Sensors with added offset voltage must be waited for after insertion into the instrument)

Load resistance: 10 ohms

Built-in filter: None

Life expectancy: 2 years (in air)

Shelf life: 1 year (from the date of shipment)

Output current polarity: Positive current (for defining the output current of carbon monoxide and hydrogen sulfide sensors)

Anti-interference characteristics:

Note: Calibration and testing must be conducted using the target gas (the gas to be measured) to ensure the accuracy of the detection and alarm equipment. The purpose of providing anti-interference data is to understand the cross-response characteristics of the sensor to certain other gases, rather than providing alternative gases for calibration: The response characteristics of cross-interference gases are not guaranteed to be linear, and there will be significant cross-gas sensitivity variations between sensor batches. Therefore, if cross-gas is used for calibration, the malt sensor cannot guarantee the accuracy of the detection and alarm equipment.

 

Specifications:

Pressure Atmospheric pressure ±10%
Pressure factor < 0.02% signal /MBar
Baseline extent <±0.4μA
Weight 5 g

 