                        Product Details:
                                                     
 
 | 
| Measuring Range: | 5 - 1000 Ppm | Sensitivity: | 55 - 100 NA/ppm In 400 Ppm CO | 
|---|---|---|---|
| Response Time: | T90 < 30s | Resolution: | < 0.5 Rms Noise | 
| Zero Current: | < ±3 Ppm | Sensitivity Drift: | < 6% | 
| Highlight: | electrochemical carbon monoxide sensor,CO gas sensor for air quality,environmental monitoring gas sensor | ||
CO-AX Electrochemical Carbon Monoxide Gas Sensor For Air Quality Monitoring Environmental Monitoring Systems
1. Product Features:
2. Product Applications:
| Measuring Range | 5 - 1000 ppm 2000 ppm (limit of performance warranty) | 
| Sensitivity | 55 - 100 nA/ppm in 400 ppm CO | 
| Response Time (T90) | < 30s from zero to 400 ppm CO | 
| Resolution | < 0.5 rms noise (ppm equivalent) | 
| Zero Current | < ±3 ppm equivalent in zero air | 
| Over Gas Limit | 4000 ppm | 
| Zero Drift | < 0.2 ppm equivalent change/year in lab air | 
| Sensitivity Drift | < 6% change/year in lab air, monthly test | 
| Operating Life | > 24 months until 80% original signal (24 - month warranted) | 
| Operating Temperature Range | -30 °C - 50 °C | 
| Pressure Range | 80 - 120 kPa | 
| Humidity Range | 15 - 90% rh continuous | 
| Storage Period | 6 months @ 0 - 20 °C | 
| Filter Capacity (H2S) | 250,000 ppm - hours | 
| Filter Capacity (NO2) | 500,000 ppm - hours | 
| Filter Capacity (NO) | 20,000 ppm - hours | 
| Filter Capacity (SO2) | 250,000 ppm - hours | 
| H2 Sensitivity (@10 °C, 900 ppm H2 in 900 ppm CO) | < 2% | 
| H2 Sensitivity (@20 °C, 900 ppm H2 in 900 ppm CO) | < 4% | 
| H2 Sensitivity (@30 °C, 900 ppm H2 in 900 ppm CO) | < 6% | 
| NO2 Sensitivity (@10 ppm NO2) | < -1% | 
| Cl2 Sensitivity (@10 ppm Cl2) | < 0.1% | 

Contact Person: Miss. Xu
Tel: 86+13352990255