Product Details:
|
| Detection Range: | 0~10PPM | Resolution: | ≤ 0.05PPM |
|---|---|---|---|
| Accuracy: | ±3% FS Or ±0.1 Ppm, Whichever Is Larger | Response Time (T90): | ≤ 25s |
| Operating Current: | 30mA | Operating Temperature Range: | -5 ~ 45 ℃ |
| Highlight: | ethylene oxide gas sensor for medical sterilization,portable EO gas detector for occupational safety,medical sterilization ventilation monitoring sensor |
||
7ETO-10 Ethylene Oxide (EO) Gas Sensor For Medical Sterilization Post-Ventilation Monitoring Portable Occupational Safety Detectors
1. Product Overview:
The 7ETO-10 is a compact, high-performance ethylene oxide (EO/ETO) gas sensor tailored for low-concentration EO detection scenarios. It adopts advanced electrochemical sensing technology to deliver reliable, real-time monitoring of EO—critical for applications where even trace EO leaks pose health, safety, or regulatory risks. With a focus on miniaturization and cost-effectiveness, it balances precision with easy integration into portable detectors, small-scale monitoring systems, and point-of-use safety devices.
2. Core Features:
3. Typical Applications:
|
Parameter Category |
Parameter Name |
Specification |
Unit |
Remarks |
|---|---|---|---|---|
| Target Gas & Sensing Principle | Target Gas | Ethylene Oxide (EO/ETO) | - | Specialized for EO; not for other toxic gases |
| Sensing Principle | Electrochemical (Three-Electrode: Working/Counter/Reference) | - | Enhances selectivity and reduces drift | |
| Measurement Performance | Detection Range | 0 ~ 10 | ppm | Custom ranges (0~5 ppm) available on request |
| Resolution | ≤ 0.05 | ppm | Minimum detectable concentration change | |
| Accuracy | ±3% FS or ±0.1 ppm, whichever is larger | - | Tested at 25℃, 1 atm, 50% RH, 5 ppm EO | |
| Response Time (T90) | ≤ 25 | Seconds | Time to reach 90% of stable output | |
| Recovery Time (T10) | ≤ 50 | Seconds | Time to drop to 10% of stable output | |
| Electrical Characteristics | Power Supply Voltage | 3.3 ~ 5.0 | V (DC) | Low power; suitable for battery-powered devices |
| Operating Current | ≤ 30 | mA | Typical value during continuous operation | |
| Output Signal Type | Option 1: Analog (0 ~ 3 V DC); Option 2: Analog (2 ~ 10 mA DC); Option 3: Digital (I2C) | - | Select output when ordering | |
| Linearity | ≥ 99.5% | - | Factory-calibrated; no external adjustment needed | |
| Environmental Adaptability | Operating Temperature Range | -5 ~ 45 | ℃ | Avoid condensation or extreme temperature swings |
| Storage Temperature Range | -20 ~ 55 | ℃ | Store in dry, dust-free, EO-free environment | |
| Operating Humidity Range | 20 ~ 85 | % RH | Non-condensing; humidity >85% RH may impact accuracy | |
| Atmospheric Pressure Range | 88 ~ 106 | kPa | Suitable for low-to-medium altitude areas | |
| Mechanical & Physical Specs | Housing Material | ABS Plastic (Standard); PC Plastic (Flame-Retardant Option) | - | Flame-retardant option meets UL94 V-0 |
| Gas Intake Mode | Diffusion (Passive) | - | No external pump required; simple installation | |
| Overall Dimensions (L×W×H) | 35 × 25 × 15 (Standard ABS version) | mm | Excludes connector; refer to 2D drawing for details | |
| Weight | ≤ 20 (ABS version); ≤ 25 (Flame-retardant PC version) | g | Net weight (no cables/fittings) | |
| Lifespan & Maintenance | Typical Operational Lifespan | ≥ 2 | Years | In clean air (EO <0.5 ppm); shorter in high EO environments |
| Calibration Interval | 6 ~ 12 | Months | Use NIST-traceable EO calibration gas (e.g., 8 ppm) |
![]()
Contact Person: Miss. Xu
Tel: 86+13352990255