Product Details:
|
| Working Principle: | Electrochemical Principle | Measurement Range: | 1 - 25% Vol. O₂ |
|---|---|---|---|
| Maximum Overload: | 30% Vol. O₂ | Output Signal: | 0.10 ± 0.02 MA In Air |
| Response Time (T90): | < 15 Seconds | Zero Current (Bias): | < 0.6% Vol. O₂ |
| Linearity: | Generally Considered Linear In Most Cases | Operating Temperature: | -20°C To +50°C |
| Highlight: | electrochemical oxygen sensor 0-30% range,oxygen gas sensor ambient measurement,YJJ 4OXV oxygen sensor with warranty |
||
Product Description:
YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration
Features:
Oxygen sensor 4OXV technical parameters
measurement
How it works: electrochemistry
Measurement range: 1-25% O2
Maximum overrun range: 30%
Signal output: 0.1 0.02mA
Response time (T90) : < 15s
Zero drift: < 0.6% O2
-ity: many cases can be regarded as -, see the specific data
Electrical parameters
Load resistance: 100 Ω
The mechanical parameters
Weight: < 16g
Shell material: ABS
Using the environment
Use temperature: - 20 to 50 ℃
Temperature: 0-20 ℃
Thermal transient: < 23.5% O2
Pressure: atmospheric pressure 20%
Pressure coefficient: < 0.02%/mBar
Pressure transient: < 200% signal change
Humidity: 5-95%RH non-condensing, short term up to 0-99% non-condensing
life
Long-term sensitivity drift: < 2%/ month
< 5%/ year typical value
Use time: 2 years
Storage time: 6 months
Specifications:
| Load resistance | 100 Ω |
| Maximum overrun range | 30% |
| Signal output | 0.1 0.02mA |
| Zero drift | < 0.6% O2 |
| Load resistance | 100 Ω |
![]()
Contact Person: Miss. Xu
Tel: 86+13352990255