Product Details:
|
| Measuring Range: | 0~5ppm | Maximum Load: | 50ppm |
|---|---|---|---|
| Working Life: | 2 Years In Air | Resolution: | 0.02 Ppm |
| Output Signal: | -1500±500nA/ PPM | Key Words: | O3 |
| Product Features: | High Precision | ||
| Highlight: | electrochemical ozone gas sensor,ozone gas sensor for environmental monitoring,YJJ O3/C-5 gas sensor |
||
Product Description:
YJJ O3/C-5 Electrochemical Ozone Gas Sensor Is Used For Environmental Monitoring
Features:
O3/ C-5 ozone sensor
Various models: O3/ c-5, O3/ c-100, O3/ c-1000, O3/ m-5, O3/ m-100, O3/ s-5, O3/ s-30000, etc
Technical parameters of O3 sensor:
O3/ c-5 measuring range: 0 ~ 5ppm maximum load: 50ppm working life: 2-year output signal in air: -1500±500nA/ PPM resolution: 0.02 PPM temperature range: -20°C to 45°C response time (T90) : less than 60sec humidity range: 15%to90% reference line: <0.1 PPM typical signal drift: less than 2% signal loss/months recommended loading resistance: 10 Ohm bias voltage: not required
High precision ozone sensor O3/ s-5
Category: ozone sensor
Product category: high precision
Key words: ozone O3
Product features: high precision
Main product parameters:
Measurement range: 0 ~ 5ppm
Zui heavy load: 50ppm
Working life: 2 years in air
Output signal: -1500±500nA/ PPM
Resolution: 0.02 PPM
Temperature range: -40°C to 45°C
Pressure range: standard atmosphere ± 10%
Less 60sec response time (T80) : less than 60sec
Relative humidity range: 15%to90%
Typical baseline range (pure air, 20 ℃) : <0.1 PPM
Zui large zero drift (20°C to 40°C) : 0.1 PPM
Long-term output drift: less 2% signal loss/months
Recommend a load resistance: 10 Ω
Bias voltage: no need
Main applications: water purification process, environmental pollution detection, atmospheric environment detection
Product name: O3/ s-30000 with high range
Category:
Product category: high range
Product features: high range
Main product parameters:
Measurement range: 0 -- 30,000 PPM
Zui big overload: 40,000 PPM
Life span: 2 years in the air
Output signal: -4.5 ± 3.5na/PPM
Resolution: 10ppm
Operating temperature range: -40 ℃ to 45 ℃
Pressure range: standard atmosphere ± 10%
T80 response time :<60 seconds
Relative humidity range :15 % to 90 % non - condensation
Typical baseline range (pure air, 20 ℃) <30ppm
Zui large zero drift (20 ° C to +40 ° C) : 30ppm
Long-term output drift: < 2% signalloss/month
Recommend a load resistance: 10 Ω
Bias voltage: no need
Main applications: water purification process, environmental pollution detection, atmospheric environment detection
Product name: high precision O3/ c-2
Category:
Product category: high precision
Key words: ozone O3
Product features: high precision
Main product parameters:
Measurement range: 0 ~ 2ppm
Zui heavy load: 10ppm
Working life: 2 years in air
Output signal: -3000±1200nA/ PPM
Resolution: 0.03 PPM
Temperature range: -40°C to 50°C
Less 60sec response time (T80) : less than 60sec
Relative humidity range: 15%to90%
Typical baseline range (pure air, 20 ℃) : <0.05 PPM
Zui large zero drift (20 ° C to +40 ° C) : 0.1 PPM
Long-term output drift: less 2% signal loss/months
Recommend a load resistance: 10 Ω
Bias voltage: no need
Main applications: water purification process, environmental pollution detection, atmospheric environment detection
Specifications:
| Measurement range | 0 - 5 ppm |
| Overload range | 50 ppm (short-term tolerance) |
| Operating life | 2 years in air |
| Output signal | -1500 ± 500 nA/ppm |
![]()
Contact Person: Miss. Xu
Tel: 86+13352990255