Product Details:
|
| Measurement Range: | 0 - 10,000 Ppm | Response Time: | T90 < 50s From Zero To 2,000 Ppm CO |
|---|---|---|---|
| Resolution: | < 5 Rms | Zero Current: | < ± 20 Ppm |
| Temperature Range: | -30 To 50 °C | Pressure Range: | 80 To 120 KPa |
| Highlight: | CO-AE carbon monoxide gas sensor,portable CO detector sensor,residential commercial carbon monoxide sensor |
||
CO-AE Carbon Monoxide Gas Sensor For Portable Carbon Monoxide (CO) Detectors Residential Commercial
Features:
Applications (Product Uses):
| Measurement Range | 0 - 10,000 ppm |
| Over Gas Range | 100,000 ppm |
| Sensitivity | 10 - 25 nA/ppm in 2,000 ppm CO |
| Response Time (t90) | < 50s from zero to 2,000 ppm CO |
| Resolution | < 5 rms noise (ppm equivalent) |
| Zero Current | < ± 20 ppm equivalent in zero air |
| Temperature Range | -30 to 50 °C |
| Pressure Range | 80 to 120 kPa |
| Humidity Range | 15 to 90% RH continuous |
| Storage Period | 6 months @ 3 to 20 °C (stored in sealed pot) |
| Load Resistor | 10 to 47 Ω |
| Weight | < 6 g |
| H2S Sensitivity | < 0.1% measured gas @ 20 ppm H2S |
| NO2 Sensitivity | < 0.1% measured gas @ 10 ppm NO2 |
| Cl2 Sensitivity | < 0.2% measured gas @ 10 ppm Cl2 |
| NO Sensitivity | < 0.1% measured gas @ 50 ppm NO |
| SO2 Sensitivity | < 0.1% measured gas @ 20 ppm SO2 |
| H2 Sensitivity | < 75% measured gas @ 400 ppm H2 at 20 °C |
| C2H4 Sensitivity | < 60% measured gas @ 400 ppm C2H4 |
| NH3 Sensitivity | < 0.1% measured gas @ 20 ppm NH3 |
| Sensitivity @ -20 °C | 65 - 93% (output @ -20 °C / output @ 20 °C) @ 400 ppm CO |
| Sensitivity @ 50 °C | 98 - 115% (output @ 50 °C / output @ 20 °C) @ 400 ppm CO |
| Zero @ -20 °C | < ± 2 ppm equivalent change from 20 °C |
| Zero @ 50 °C | < ± 5 ppm equivalent change from 20 °C |
![]()
Contact Person: Miss. Xu
Tel: 86+13352990255