logo
Home ProductsGas Sensor

YJJ 1O2 AAW85-07WA-CIT Electrochemical Oxygen O2 Gas Sensor Is Used For Industrial Safety

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

YJJ 1O2 AAW85-07WA-CIT Electrochemical Oxygen O2 Gas Sensor Is Used For Industrial Safety

YJJ 1O2 AAW85-07WA-CIT Electrochemical Oxygen O2 Gas Sensor Is Used For Industrial Safety
YJJ 1O2 AAW85-07WA-CIT Electrochemical Oxygen O2 Gas Sensor Is Used For Industrial Safety YJJ 1O2 AAW85-07WA-CIT Electrochemical Oxygen O2 Gas Sensor Is Used For Industrial Safety YJJ 1O2 AAW85-07WA-CIT Electrochemical Oxygen O2 Gas Sensor Is Used For Industrial Safety YJJ 1O2 AAW85-07WA-CIT Electrochemical Oxygen O2 Gas Sensor Is Used For Industrial Safety

Large Image :  YJJ 1O2 AAW85-07WA-CIT Electrochemical Oxygen O2 Gas Sensor Is Used For Industrial Safety

Product Details:
Place of Origin: Britain
Brand Name: YJJ
Model Number: 1O2 AAW85-07WA-CIT
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Pouching
Delivery Time: 5-8 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 1500

YJJ 1O2 AAW85-07WA-CIT Electrochemical Oxygen O2 Gas Sensor Is Used For Industrial Safety

Description
Working Principle: Lead-free Electrochemical Principle Power Supply Voltage: 3 - 3.6V DC
Power Consumption: 0.48mW Operating Current: 146.79μA
Measurement Range: 0% - 25% Vol O2 Resolution: 0.1% O2
Highlight:

industrial oxygen gas sensor

,

electrochemical O2 sensor

,

safety oxygen sensor with warranty

Product Description:

YJJ 1O2 AAW85-07WA-CIT Electrochemical Oxygen O2 Gas Sensor Is Used For Industrial Safety

 

Features:

Oxygen (O2) simulates a gas sensor

Main features and advantages

Commissioning of small instruments

Designed to meet global performance standards.

The ANSI/ISA 92.04.01:2007

BS EN 50104:2010

AS/NZS 4641-2007

Improve performance across extended environments

Five years of expected operating life

Conforms to RoHS and lead free electrochemical design

Technical specifications

measurement

Lead free electrochemical technology

Measurement range 0.6%vol.O2 to 25%vol.O2.

Max overload 30%vol.O2

Airborne filter None

Sensitivity * 80 mA to 130 mA (in air).

T50 Response time *

< 10 seconds (at 20°C)

< 15 seconds (at -40°C to +60°C)

T90 response time * normal < 15 seconds

R90 Recovery time *< 45 seconds (@20°C to +60°C).

R95 Recovery time; 60 seconds

Zero current (offset)(N2 after 3 minutes)

< 0.6% vol.O2 equivalent normally < 0.3% vol.O2 equivalent

For the preheating time, see the feature description

Repetition. ±5% of the measured value.

Linear S=K loge 1/(1-c)

 

 

Specifications:

Measurement Range 0.6% vol. O2 to 25% vol. O2
Maximum Overload 30% vol. O2
Sensitivity 80 mA to 130 mA in Air
T50 Response Time < 10 seconds (@ 20°C)
< 15 seconds (@ -40°C to +60°C)

 