logo
Home ProductsGas Sensor

YJJ 0390 0070 Oxygen Sensor Is Used Smoke Gas Analyzers Of Models Such As Testo 300 335 350 Etc

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

YJJ 0390 0070 Oxygen Sensor Is Used Smoke Gas Analyzers Of Models Such As Testo 300 335 350 Etc

YJJ 0390 0070 Oxygen Sensor Is Used Smoke Gas Analyzers Of Models Such As Testo 300 335 350 Etc
YJJ 0390 0070 Oxygen Sensor Is Used Smoke Gas Analyzers Of Models Such As Testo 300 335 350 Etc YJJ 0390 0070 Oxygen Sensor Is Used Smoke Gas Analyzers Of Models Such As Testo 300 335 350 Etc YJJ 0390 0070 Oxygen Sensor Is Used Smoke Gas Analyzers Of Models Such As Testo 300 335 350 Etc

Large Image :  YJJ 0390 0070 Oxygen Sensor Is Used Smoke Gas Analyzers Of Models Such As Testo 300 335 350 Etc

Product Details:
Place of Origin: Germany
Brand Name: Testo
Model Number: 0390 0070
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Palletized
Delivery Time: 5-8 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 2200

YJJ 0390 0070 Oxygen Sensor Is Used Smoke Gas Analyzers Of Models Such As Testo 300 335 350 Etc

Description
Hydrogen Sulfide (H2S): 0-4000 PPM Operating Temperature: -20℃ To +50℃
CO: 0-500 PPM (in Increments Of 1 PPM) O2: 0-30.0% Vol. (increment 0.1% Vol.)
Flammable Gas (LEL): 0-100% (LEL Increment Is 1%) Or Methane: 0-5.0% V/V
Highlight:

YJJ 0390 oxygen sensor for Testo analyzers

,

gas sensor for Testo 300 335 350

,

oxygen sensor replacement for smoke analyzers

Product Description:

YJJ 0390 0070 Oxygen Sensor Is Used in Smoke Gas Analyzers of Models Such As Testo 300 335 350 Etc

 

Features:

0390 0070 Oxygen Sensor, which is often used as a backup or replacement sensor for smoke gas analyzers of the testo 300 series, 335, 350 and other models. The core function is to accurately detect the oxygen concentration in the smoke gas. The following is the detailed parameter and usage introduction of it:
Core Parameters
Parameter Category
Core Measurement Parameters The detection target is oxygen, the sensor type is TO2Bi, it is compatible with many mainstream smoke gas analyzers of Datong, and has strong compatibility for replacement
Service Life Under normal usage conditions, the sensor service life is approximately 2.5 - 3 years. The service life is less related to the number of measurements, and is suitable for long-term and high-frequency smoke gas detection scenarios
Compatible Equipment It is specifically matched with testo 300M, 300XL, 300XXL and other 300 series smoke gas analyzers, and is also applicable to testo 335, old model testo 350 and other types of analyzers
Complementary Features As a standardized replacement part, the installation operation is convenient, no complex debugging process is required, and the sensor replacement can be completed quickly to ensure the continuity of smoke gas detection work Main purpose
Industrial combustion equipment smoke gas detection: The testo 300 series analyzers are suitable for smoke gas detection of factory boilers, industrial burners and other equipment. By monitoring the oxygen concentration in the smoke gas, it is possible to determine whether the fuel combustion is sufficient. For example, when the oxygen concentration is too high, it indicates that there is an excess of air during the combustion process, which will cause energy waste; when the concentration is too low, it indicates that the combustion is incomplete, and harmful gases such as carbon monoxide may be produced, providing data basis for adjusting the combustion system.
Maintenance of small commercial combustion equipment: It can be used for smoke gas monitoring of large cooking appliances and small heating boilers in commercial equipment such as restaurants. These equipment may have abnormal combustion conditions after long-term use. By using this sensor to detect the oxygen concentration, it can promptly discover potential faults in the combustion system and assist maintenance personnel in conducting debugging and maintenance, ensuring the safe and efficient operation of the equipment.
Reserve of smoke gas analyzer accessories: It is a commonly used reserve part for environmental protection testing institutions and enterprise equipment operation and maintenance departments. Due to the fact that the smoke gas analyzer works in a high-temperature and dusty smoke gas environment for a long time, the sensor is prone to performance degradation. Reserving this type of sensor can enable quick replacement in case of the original sensor failure, avoiding the impact on environmental protection testing tasks or the progress of equipment operation and maintenance due to equipment shutdown.

 

Specifications:

Hydrogen sulfide (H2S) 0-4000 PPM
CO 0-500 PPM (in increments of 1 PPM)
O2 0-30.0% vol. (increment 0.1% vol.)
Flammable gas (LEL) 0-100% (LEL increment is 1%) or

 

YJJ 0390 0070 Oxygen Sensor Is Used Smoke Gas Analyzers Of Models Such As Testo 300 335 350 Etc 0

Contact Details
ShenzhenYijiajie Electronic Co., Ltd.

Contact Person: Miss. Xu

Tel: 86+13352990255

Send your inquiry directly to us (0 / 3000)