logo
Home ProductsGas Sensor

C03-0801-000 Whittle LEL Catalytic Combustion (Whittle) LEL Sensor Module for Fixed Industrial Monitoring Systems

Certification
china ShenzhenYijiajie Electronic Co., Ltd. certification
china ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

C03-0801-000 Whittle LEL Catalytic Combustion (Whittle) LEL Sensor Module for Fixed Industrial Monitoring Systems

C03-0801-000  Whittle LEL Catalytic Combustion (Whittle) LEL Sensor Module for Fixed Industrial Monitoring Systems
C03-0801-000  Whittle LEL Catalytic Combustion (Whittle) LEL Sensor Module for Fixed Industrial Monitoring Systems C03-0801-000  Whittle LEL Catalytic Combustion (Whittle) LEL Sensor Module for Fixed Industrial Monitoring Systems C03-0801-000  Whittle LEL Catalytic Combustion (Whittle) LEL Sensor Module for Fixed Industrial Monitoring Systems

Large Image :  C03-0801-000 Whittle LEL Catalytic Combustion (Whittle) LEL Sensor Module for Fixed Industrial Monitoring Systems

Product Details:
Place of Origin: UK
Model Number: C03-0801-000 Whittle LEL
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Paper box
Delivery Time: 3-5work days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 5000pcs

C03-0801-000 Whittle LEL Catalytic Combustion (Whittle) LEL Sensor Module for Fixed Industrial Monitoring Systems

Description
Measurement Range: 0~100% LEL Resolution: 1% LEL
Accuracy: ±5% FS Response Time (T90): ≤15 S
Operating Life: 2 Years (in Air) Sensitivity: Typical 50 MV/100% LEL
Highlight:

Whittle LEL catalytic combustion sensor

,

fixed industrial gas sensor module

,

LEL sensor for monitoring systems

 

            C03-0801-000 Whittle LEL Catalytic Combustion (Whittle) LEL Sensor Module for Fixed Industrial Monitoring Systems

 

 

Key Features:

 
  1. High-performance catalytic combustion detection: Adopts Whittle principle for reliable 0~100% LEL combustible gas monitoring, calibrated with methane (CH4) as the standard gas for universal industrial applicability.
  2. Ultra-fast response: T90 ≤15s ensures rapid detection of sudden flammable gas leaks and timely safety alerts for on-site personnel.
  3. Wide environmental tolerance: Operates in -40°C to 75°C temperature range and 80–120 kPa pressure range, with 15–90% non-condensing humidity resistance, suitable for extreme harsh industrial working conditions.
  4. Low cross-sensitivity: Special filtered design minimizes interference from H2S, CO and volatile organic compounds (VOCs), reducing false alarms and ensuring measurement accuracy.
  5. Easy integration & replacement: Standard 4R+ analog module design, direct interchangeable with Honeywell BW matching detectors, no complex wiring, enabling quick on-site sensor replacement.
  6. Global safety certifications: Compliant with ATEX, IECEx and UL certification standards, meeting the flammable gas detection safety requirements of different countries and industrial fields.
  7. Stable long-term performance: 2-year operational life in air, ±5% FS high accuracy and 1% LEL high resolution, reducing frequent calibration and maintenance costs for industrial users.
  8. Overload resistance: Withstands short-term 120% LEL gas overload without permanent damage, adapting to sudden high-concentration flammable gas leakage scenarios on site.

 

Product Applications:

 
This catalytic combustion Whittle LEL sensor is engineered for industrial combustible gas safety monitoring, ideal for harsh on-site and confined space scenarios, mainly applied in:
 
  1. Portable industrial gas detection: Integrated into Honeywell BW RigRat and 4R+ series multi-gas detectors for real-time monitoring of flammable gas leaks in oil & gas, mining, petrochemical and construction sites.
  2. Confined space entry safety: Pre-entry and continuous detection of combustible gas concentrations (0–100% LEL) in tanks, manholes, pipelines and underground vaults to prevent explosion and fire hazards.
  3. Harsh environment flammable gas monitoring: Used in high/low temperature, high-altitude and dusty industrial working conditions for process safety and equipment leak detection in refineries, wellheads and chemical plants.
  4. Field rapid gas screening: Serves as a core sensing component for hand-held flammable gas detectors, supporting quick on-site hazard assessment and emergency response decision-making.

 

Model C03-0801-000 (4R+ Whittle LEL Analog Sensor)
Detection Principle Catalytic combustion (Whittle)
Measurement Range 0–100% LEL
Resolution 1% LEL
Accuracy ±5% FS
Response Time (T90) ≤15 s
Output Signal Analog (4R+ module standard)
Sensitivity Typical 50 mV/100% LEL
Operating Life 2 years (in air)
Operating Conditions Temperature: -40°C to 75°C; Humidity: 15–90% RH (non-condensing); Pressure: 80–120 kPa
Interference Resistance Low cross-sensitivity to H2S, CO, and VOCs

 