Product Details:
|
| Range: | 0–50 Ppm | Maximum Overload: | 100 Ppm |
|---|---|---|---|
| Sensitivity: | 0.10 ± 0.02 μA/ppm | T90 Response: | ≤120 S |
| Highlight: | HCN gas sensor electrochemical,hydrogen cyanide sensor 3-electrode,gas detector with warranty |
||
4HCN CLE‑0731‑4000 Hydrogen Cyanide (HCN) Gas Sensor 3-Electrode Electrochemical
Application Scenarios
* Electroplating, metallurgy, gold mining (cyanide processes)
* Chemical, pharmaceutical, synthetic fiber
* Flue gas/incinerators, laboratory fume hoods
* Portable/fixed HCN detectors, safety instrumented systems
Selection Recommendations
* Regular occupational exposure (≤10 ppm): Select 4HCN-10S
* Industrial leakage/high concentration: Select 4HCN-50S
* Replace CITY 4HN: Direct pin compatibility, 0 mV bias, no circuit modification required
Specification:
| Resolution | 0.1 ppm |
| Bias Voltage | 0 mV (No polarization required) |
| Measurement Range | 0–50 ppm |
| Sensitivity | 0.065 ± 0.020 μA/ppm |
| T90 Response | ≤105 s |
| Baseline | < ±0.2 μA |
| Resolution | 0.2 ppm |
| Bias Voltage | 0 mV |
![]()
Contact Person: Xu
Tel: 86+13352990255