| Detection Of Gas: | O2 | Measurement Range: | 1% - 96 Vol.% O₂ |
|---|---|---|---|
| Output Signal: | Microcurrent | Output: | 15 - 30 μA |
| Full Scale: | 96% O₂ | Maximum: | 420 μA |
| Accuracy: | ±1.0% O₂ | Repeatability: | <0.2% O₂ |
| Highlight: | Zirconia-based oxygen sensor,Limit current oxygen sensor,Medical oxygen sensor 1%-96% |
||
Product Description:
YJJ SO-E2-960 Zirconia-Based Limit Current Oxygen Sensor for 1% - 96 vol.% O2 Medicine
Features:
I. Basic Principles
This device adopts the ZrO₂ limit current principle. After high-temperature heating, oxygen ions migrate in the electrolyte, and the saturation limit current is linearly proportional to the oxygen concentration. It is specifically designed for high-concentration oxygen-rich environments, not a sulfur dioxide sensor.
II. Core Electrical and Performance Parameters
1. Measurement Specifications
Detected gas: O₂ (oxygen)
Measurement range: 1% - 96 vol.% O₂ (covering the range from air to pure oxygen)
Output signal: Limit microcurrent. In air (20.9% O₂), the output is 15 - 30 μA; at full scale, 96% O₂, the maximum is 420 μA
Accuracy: ±1.0% O₂; repeatability < 0.2% O₂
Linearity: Approximately linear over the full range, with minimal temperature drift
Cross-sensitivity: Low. Inert gases such as nitrogen and argon have almost no interference
2. Heating and Power Supply Parameters
Standard heating voltage: 3.6 VDC (compatible with 3.6 - 4.4V range)
Heating cold resistance (25°C): 3.25Ω ± 0.2Ω
Overall power consumption: 1.3 - 1.8W, typical 1.4W
Sensor bias voltage: 0.7 - 1.6 VDC
Preheating requirement: At least 30s, stable for approximately 2 minutes
3. Response and Gas Path
t90 response time: 2 - 25s (depending on gas flow rate and chamber)
Recommended gas flow rate: 250ml/min; allowed range 100 - 500ml/min
Gas diffusion: Diffusion of gas through the top metal filter screen
4. Environment and Lifespan
Maximum temperature resistance without cable: 350°C; with lead wire cable: up to 125°C
Working humidity: ≤ 90% RH. Prohibition of condensation
Air pressure range: 700 - 1300mbar (standard atmospheric pressure)
Nominal lifespan MTTF: 20,000 hours (continuous operation approximately 2.3 years)
Package size: TO-8 metal package, outer diameter 15.3mm, height 13.7mm, straight insertion 4-pin PCB installation
Compliance: RoHS environmental protection
III. Product Core Advantages
Extremely wide range: Covers the range from 21% to 96% oxygen in air, suitable for oxygen-enriched scenarios for oxygen generation
Extremely low temperature drift: Stable signals in high-temperature conditions, no need for complex temperature compensation circuits
Simple calibration: Most conditions only require a single-point calibration with air, low maintenance cost
Long lifespan: Compared to electrochemical oxygen sensors, the lifespan is increased by several times
Resistant to interference from inert gases, suitable for nitrogen replacement, low-oxygen/high-oxygen alternating environments
IV. Industry Application Scenarios
1. Medical Equipment (Main Application)
Home/medical oxygen generators, oxygen concentrators: Real-time monitoring of output oxygen concentration, oxygen deficiency alarm, concentration closed-loop control
Cell culture chambers, medical constant-temperature oxygen cabins, oxygen concentration detection for ventilators
2. Laboratories and Precision Manufacturing
Suitable for glove boxes, inert gas nitrogen cabinets, semiconductor storage cabinets: Monitoring trace amounts of oxygen to prevent component oxidation
Material anaerobic experiments, anaerobic incubators, welding inert protection atmosphere monitoring
3. Food Preservation Industry
Gas-maintained packaging (MAP), low-oxygen environment monitoring for fruits and vegetables storage
Oxygen content control in baking ovens, oxygen concentration monitoring in fermentation tanks
4. Industrial Safety and Heat Treatment
Nitrogen anti-oxidation storage, electronic component drying cabinets
Oxygen detection in heat treatment furnaces, inert welding protection gas monitoring
Nitrogen fire suppression monitoring in server rooms, low-oxygen storage in wine cellars
5. Portable/Fixed Oxygen Analyzers
Handheld oxygen detection instrument, online high-purity oxygen monitoring instrument, oxygen detection for diving equipment
Specifications:
| O₂ oxygen | 1% - 96 vol.% O₂ |
| Standard heating voltage | 3.6 VDC |
| Compatible within the range | 3.6 to 4.4V |
| Heating cold resistance | 3.25Ω ± 0.2Ω |
| Overall power consumption | 1.3 to 1.8W |
| Sensor bias voltage | 0.7 to 1.6 VDC |
![]()