logo
Home ProductsGas Sensor

ETO/M-10 Electrochemical Ethylene Oxide Gas Sensor for Detecting Toxic Carcinogenic Ethylene Oxide Gas in Industrial

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

ETO/M-10 Electrochemical Ethylene Oxide Gas Sensor for Detecting Toxic Carcinogenic Ethylene Oxide Gas in Industrial

ETO/M-10 Electrochemical Ethylene Oxide Gas Sensor for Detecting Toxic Carcinogenic Ethylene Oxide Gas in Industrial
ETO/M-10 Electrochemical Ethylene Oxide Gas Sensor for Detecting Toxic Carcinogenic Ethylene Oxide Gas in Industrial ETO/M-10 Electrochemical Ethylene Oxide Gas Sensor for Detecting Toxic Carcinogenic Ethylene Oxide Gas in Industrial ETO/M-10 Electrochemical Ethylene Oxide Gas Sensor for Detecting Toxic Carcinogenic Ethylene Oxide Gas in Industrial ETO/M-10 Electrochemical Ethylene Oxide Gas Sensor for Detecting Toxic Carcinogenic Ethylene Oxide Gas in Industrial ETO/M-10 Electrochemical Ethylene Oxide Gas Sensor for Detecting Toxic Carcinogenic Ethylene Oxide Gas in Industrial

Large Image :  ETO/M-10 Electrochemical Ethylene Oxide Gas Sensor for Detecting Toxic Carcinogenic Ethylene Oxide Gas in Industrial

Product Details:
Place of Origin: Switzerland
Model Number: ETO/M-10
Payment & Shipping Terms:
Minimum Order Quantity: 1PCS
Price: Negotiable
Packaging Details: Paper box
Delivery Time: 5-8 work days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 5000PCS

ETO/M-10 Electrochemical Ethylene Oxide Gas Sensor for Detecting Toxic Carcinogenic Ethylene Oxide Gas in Industrial

Description
Nominal Measuring Range: 0 ~ 10 Ppm Maximum Overload Range: 100 Ppm
Sensitivity (@20°C): 1.9 ± 0.8 μA/ppm Zero Signal (@20°C): -0.2 ~ 2.5 μA
T90 Response Time: ≤ 120 S Resolution: 0.05 Ppm
Highlight:

ETO/M-10 ethylene oxide gas sensor

,

electrochemical toxic gas detector

,

industrial ethylene oxide sensor

 

               ETO/M-10 Electrochemical Ethylene Oxide Gas Sensor for Detecting Toxic Carcinogenic Ethylene Oxide Gas in Industrial

 

 

Product Features:

  • Professional ETO Detection Performance: Specially developed for ethylene oxide toxic gas monitoring, with accurate response within the professional detection range, meeting industrial safety and environmental detection standard requirements.
  • High Measurement Stability & Low Drift: Optimized four-electrode structure and internal electrolyte formula effectively suppress temperature and humidity drift, ensuring consistent long-term output data without frequent calibration.
  • Controlled Cross-Sensitivity: Reasonable anti-interference design reduces response to common interfering gases such as carbon monoxide, isobutylene and ethanol, effectively avoiding false alarms in complex industrial environments.
  • Moderate Fast Response Speed: Standard T90 response time adapts to slow-changing ETO concentration in sterilization workshops and closed spaces, realizing accurate and stable concentration capture.
  • Strong Environmental Adaptability: Supports wide temperature and humidity working range, maintains stable detection performance in high-humidity and variable-temperature industrial sterilization environments.
  • Industrial-Grade Durability: High-quality sealed structure and stable electrochemical core, with rated service life up to 24 months under standard working conditions, reducing equipment replacement and maintenance costs.
  • Standard Compatibility & Easy Integration: Universal size and analog current output mode, compatible with mainstream industrial acquisition circuits and detection equipment, convenient for secondary development and system integration.
  • High Resolution & Low Noise: Ultra-high resolution capability enables trace ETO concentration identification, meeting refined safety monitoring and residual gas detection requirements.

Product Applications:

The ETO/M-10 ethylene oxide sensor is dedicated to real-time monitoring and leakage early warning of ethylene oxide gas, widely used in industries involving ETO sterilization, production and storage:
  • Medical & Pharmaceutical Industry: Residual ethylene oxide monitoring in medical device sterilization workshops, pharmaceutical factory ETO disinfection rooms and sterile production workshops to ensure personnel safety and environmental compliance.
  • Industrial Sterilization & Disinfection: Real-time gas detection and leakage alarm for ETO sterilization equipment, closed sterilization cabins and post-sterilization ventilation environments.
  • Chemical Production & Storage: Safety monitoring of ethylene oxide production workshops, storage warehouses, transportation pipelines and chemical processing workshops to prevent toxic gas leakage accidents.
  • Environmental Compliance Monitoring: Factory exhaust gas detection and workshop atmospheric ETO concentration monitoring, supporting industrial environmental protection supervision and emission compliance assessment.
  • Portable Safety Inspection: Matched with handheld toxic gas detectors for on-site rapid detection, daily safety inspection and hidden danger troubleshooting in ETO working areas.
  • Confined Space Operation Monitoring: Real-time concentration monitoring of closed workshops, isolated disinfection spaces and low-ventilation ETO operation areas to guarantee operator occupational safety.

 

 

Product Model ETO/M-10
Sensor Type 4-Electrode Electrochemical Ethylene Oxide Sensor
Detection Gas Ethylene Oxide (ETO / C2H4O)
Nominal Measuring Range 0 ~ 10 ppm
Maximum Overload Range 100 ppm
Sensitivity (@20°C) 1.9 ± 0.8 μA/ppm
Zero Signal (@20°C) -0.2 ~ 2.5 μA
T90 Response Time ≤ 120 s
Resolution 0.05 ppm
Temperature Baseline Shift < 2 ppm (-20°C ~ +50°C)
Long-Term Output Drift < 2% signal/month
Rated Service Life ≥ 24 months (standard clean air conditions)
Working Temperature Range -20°C ~ +50°C
Working Humidity Range 15% ~ 90% RH (non-condensing)
Working Pressure Range 90 ~ 110 kPa
Recommended Storage Conditions 10°C ~ 30°C, sealed storage
Shelf Life 6 months (original sealed packaging)

 

ETO/M-10 Electrochemical Ethylene Oxide Gas Sensor for Detecting Toxic Carcinogenic Ethylene Oxide Gas in Industrial

Contact Details
ShenzhenYijiajie Electronic Co., Ltd.

Contact Person: Miss. Xu

Tel: 86+13352990255

Send your inquiry directly to us (0 / 3000)