|
Product Details:
|
| Measurement Range: | 400 - 5000 Ppm | Resolution: | 1 Ppm |
|---|---|---|---|
| Detection Accuracy: | 25℃ | T90 Response Time: | < 120s |
| Preheating Stabilization Time: | 60s | Long-term Zero Drift: | ≤ 2% FS / Month |
| Non-linearity Error: | ≤ 1% FS | Power Supply Voltage: | DC 5.0V ± 0.1V |
| Highlight: | NDIR CO2 sensor for greenhouses,CO2 sensor for HVAC systems,5000ppm CO2 gas sensor |
||
Product Description:
YJJ TC-3000 NDIR CO2 Sensor 400–5000ppm Greenhouses Factories and Indoor HVAC Systems
Features:
I. Basic Overview
Model: TC-3000
Detection Principle: Non-dispersive Infrared NDIR Detection Principle, with built-in temperature automatic compensation
Detected Gas: CO₂ Carbon Dioxide
Standard Measurement Range: 400 - 5000 ppm (can cover the base atmospheric 400 ppm baseline downward)
II. Core Sensor Performance Parameters
Measurement Range: 400 ~ 5000 ppm
Resolution: 1 ppm
Detection Accuracy: ±(50 ppm + 5% FS) (normal temperature 25℃ operating condition)
T90 Response Time: < 120s
Preheating Stability Time: 60s
Zero Point Long-Term Drift: ≤ 2% FS / Month; Equipped with Automatic Baseline Calibration Function
Non-Linearity Error: ≤ 1% FS
III. Electrical Parameters
Power Supply Voltage: DC 5.0V ± 0.1V
Average Working Current: < 40mA; Peak Current ≤ 125mA
Output Mode: TTL-UART, PWM, 0 - 5V Analog Voltage Signal
3.3V Level Output, compatible with single-chip microcontroller mainboard
IV. Environmental Applicable Specifications
Operating Temperature: -10℃ ~ +50℃
Storage Temperature: -20℃ ~ +60℃
Operating Humidity: 0 - 95% RH, Prohibited Water Vapor Condensation
Gas Chamber: Gold-plated anti-corrosion inner cavity, resistant to moisture and interference from corrosive gases, sensor will not be poisoned or fail
V. Hardware Structure
Shell: Small Diffusion Gas Chamber Structure, Convenient Installation Hole
Expected Service Life: 5 - 8 Years, Infrared Principle is not affected by oxygen concentration
VI. Product Advantages
Gold-plated Gas Chamber, Anti-corrosion, Built-in Temperature Compensation, Anti-Water Vapor Interference, Baseline Automatic Calibration, Multiple Signal Output, Installation Simple, High Cost Performance
VII. Detailed Application Scenarios
Agricultural Greenhouse and Garden: Control CO₂ Concentration, Improve Crop Photosynthetic Efficiency
Indoor Air Monitoring: Office, Classroom, Supermarket, Dormitory, Underground Garage Risk Control System
Confined Spaces: Underground Pipeline, Cellar, Container, Storage Chamber CO₂ Excess Alarm
Fresh Air Equipment, Air Purifier, Building HVAC Ventilation Unit
Incubation Room, Breeding Shed, Fermentation Workshop, Laboratory Environmental Monitoring
Portable Air Quality Detector, IoT Environmental Monitoring Terminal Accessories
Specifications:
| Operating humidity | < 40mA |
| Storage temperature | -20℃ ~ +60℃ |
| Operating temperature | -10℃ ~ +50℃ |
| Output mode | TTL-UART, PWM |
| Average operating current | <30g |
![]()
Contact Person: Miss. Xu
Tel: 86+13352990255