Product Details:
|
| Measurement Principle: | NDIR (Non-Dispersive Infrared) | Measurement Range: | 0–5% Vol CO₂ (50,000 Ppm) |
|---|---|---|---|
| Accuracy: | ±70 Ppm ±5% | Reading Resolution: | 10 Ppm |
| Highlight: | CO2 gas sensor low power consumption,NDIR infrared CO2 sensor,ExplorIR-W-5 CO2 gas sensor |
||
COZIR-WX-5 ExplorIR-W-5 NDIR Infrared CO2 Gas Sensor Low Power Consumption
Typical Applications
- Sealed compartments, diving equipment, fermentation processes
- Industrial safety, battery-powered portable CO₂ detectors
- Greenhouses, high-concentration CO₂ environmental monitoring
Specification:
| Power Consumption | Typical 3.5 mW; Peak 33 mA, Average <1.1 mA |
| Resolution | 10 ppm |
| Power Supply | 3.2–5 V DC (3.3 V recommended) |
| Interface | TTL-UART, 9600-8-1-N; ASCII command protocol |
| Sampling Rate | 2 Hz (500 ms) |
| Warm-up Time | <10 s |
| T90 Response | 4 s (filtering parameters configurable up to 2 min) |
| Operating Temperature | 0–50°C; Extended range -25–55°C |
| Humidity | 0–95% RH (non-condensing) |
| Pressure | 950 mbar–10 bar |
| Lifespan | >15 years; Sampling method: diffusion (external gas tubing connector available) |
| Weight | Approx. 8 g |
![]()
Contact Person: Xu
Tel: 86+13352990255