CL2-B1 Electrochemical Chlorine (Cl2) Sensor Module for Water Treatment Plant Safety Monitoring Environmental Protection Exhaust
CL2-B1 Electrochemical Chlorine (Cl2) Sensor Module for Water Treatment Plant Safety Monitoring Environmental Protection Exhaust CL2-B1 Electrochemical Chlorine (Cl2) Sensor Module for Water Treatment Plant Safety Monitoring Environmental Protection Exhaust CL2-B1 Electrochemical Chlorine (Cl2) Sensor Module for Water Treatment Plant Safety Monitoring Environmental Protection Exhaust CL2-B1 Electrochemical Chlorine (Cl2) Sensor Module for Water Treatment Plant Safety Monitoring Environmental Protection Exhaust CL2-B1 Electrochemical Chlorine (Cl2) Sensor Module for Water Treatment Plant Safety Monitoring Environmental Protection Exhaust CL2-B1 Electrochemical Chlorine (Cl2) Sensor Module for Water Treatment Plant Safety Monitoring Environmental Protection Exhaust

Large Image :  CL2-B1 Electrochemical Chlorine (Cl2) Sensor Module for Water Treatment Plant Safety Monitoring Environmental Protection Exhaust

Product Details:
Place of Origin: UK
Model Number: CL2-B1 Module
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Paper box
Delivery Time: 5-8 work days
Payment Terms: L/C, D/A, D/P, T/T
Supply Ability: 5000pcs

CL2-B1 Electrochemical Chlorine (Cl2) Sensor Module for Water Treatment Plant Safety Monitoring Environmental Protection Exhaust

Description
Detected Gas: Chlorine (Cl2) Working Principle: Three-electrode Electrochemical Detection
Measuring Range: 0-20 Ppm Resolution: 0.02 Ppm
Sensitivity: -600 ~ -1150 NA/ppm Response Time (T90): ≤60 S
Highlight:

electrochemical chlorine sensor module

,

Cl2 sensor for water treatment

,

chlorine gas sensor with warranty

 

              CL2-B1 Electrochemical Chlorine (Cl2) Sensor Module for Water Treatment Plant Safety Monitoring Environmental Protection Exhaust

 

 

 

 

Core Features:

Benefiting from the large-cavity electrochemical structure and industrial-grade optimized design, the CL2-B1 chlorine sensor achieves high accuracy, superior stability, strong moisture resistance, low false alarm rate and long service life for harsh industrial working conditions:
  • Ultra-high Precision Trace Detection: The measuring range is 0-20 ppm with ultra-fine resolution of 0.02 ppm, capable of capturing minimal chlorine leakage and low-concentration abnormal changes, fully meeting industrial safety limit and environmental micro-emission detection standards.
  • Large Cavity Anti-drift Design: Equipped with large-capacity electrolyte cavity structure, which greatly improves environmental adaptability, effectively suppresses baseline drift caused by high humidity and temperature changes, and ensures stable and non-fluctuating long-term sampling data.
  • Excellent High Humidity Adaptability: Optimized for high-humidity and water-vapor-rich working sites, it operates stably in humid factory workshops and outdoor open monitoring environments without moisture failure or virtual high data deviation.
  • Fast Response and Early Warning: Sensitive electrochemical reaction ensures rapid response to sudden chlorine concentration changes, providing timely leakage abnormality feedback and sufficient safety response time for on-site risk disposal and ventilation linkage.
  • Strong Gas Selectivity and Low False Alarm Rate: Features exclusive selective response to chlorine gas, effectively shielding most conventional interfering gases and accurately identifying true Cl2 concentration, minimizing false and missing alarms in complex industrial environments.
  • Wide Temperature and Humidity Working Range: Supports operating temperature from -20℃ to 50℃ and working humidity of 15%–90% RH, adapting to drastic temperature changes and humid harsh industrial conditions with strong environmental tolerance.
  • Industrial Corrosion and Aging Resistance: Core components adopt chemical corrosion-resistant and anti-aging materials, resisting erosion by acidic and oxidizing gases in chemical plants and reducing equipment failure rate effectively.
  • Long-term Online Monitoring Reliability: Specially designed for fixed industrial online monitoring equipment, supporting year-round uninterrupted continuous operation with stable service life and low overall equipment maintenance cost.

Applications:

The CL2-B1 sensor module is dedicated to industrial toxic chlorine leakage monitoring and environmental compliance detection, widely deployed in high-humidity harsh working conditions and fixed online safety monitoring scenarios:
  • Water Treatment Plant Safety Monitoring: Applied in municipal sewage and industrial wastewater treatment plants to monitor chlorine leakage and residual tail gas during disinfection processes, preventing personnel poisoning and factory gas exceeding standards to ensure safe operation of water treatment sections.
  • Pharmaceutical Disinfection Process Monitoring: Deployed in pharmaceutical factory disinfection processes and chlorine sterilization stations to monitor residual chlorine concentration in workshop tail gas, ensuring compliant operating environment and protecting occupational health of workers.
  • Environmental Protection Exhaust and Park Monitoring: Integrated into park environmental monitoring micro-stations and enterprise unorganized emission monitoring equipment to accurately collect chlorine emission data, meeting environmental inspection, data traceability and standardized management requirements.
  • Industrial Ventilation and Exhaust Gas Treatment Monitoring: Installed at the inlet and outlet of exhaust gas scrubbers, ventilation systems and tail gas treatment equipment to monitor chlorine concentration changes, ensuring qualified exhaust gas discharge and stable treatment efficiency.
  • Fixed Industrial Safety Alarm System Integration: Massively matched with fixed chlorine detectors, industrial gas alarm hosts and factory safety monitoring systems to realize all-weather unattended early warning and intelligent linkage control for high-risk areas.

 

Model CL2-B1
Detected Gas Chlorine (Cl2)
Working Principle Three-electrode Electrochemical Detection
Measuring Range 0–20 ppm
Resolution 0.02 ppm
Sensitivity -600 ~ -1150 nA/ppm
Response Time (T90) ≤60 s
Maximum Overload 60 ppm
Zero Current ±0.4 nA
Operating Temperature -20℃ ~ +50℃
Operating Humidity 15% ~ 90% RH (Non-condensing)
Operating Pressure 80 ~ 120 kPa
Mechanical Size Φ32.3 × 16.5 mm
Service Life 2 Years (24-month warranty)
Storage Period 6 Months

 

 