Product Details:
|
| Detection Gas: | VOC | Principle: | PID Photoionization |
|---|---|---|---|
| Range: | 0 - 2000 Ppm | Resolution: | 0.1 Ppm |
| UV Lamp Energy: | 10.6 EV | Operating Temperature: | -20 ~ +55 ℃ |
| Expected Lifespan: | 1 Year | Packaging: | Bagged |
| Highlight: | PID VOC sensor 10.6eV,photoionization gas sensor MX6 iBrid,industrial VOC sensor replacement |
||
Product Description:
YJJ 17124975-R PID Photoionization VOC Sensor 10.6eV for Industrial Scientific MX6 iBrid
Features:
Principle: PID Photoionization - UV lamp emitting 10.6 eV light, specifically for detecting volatile organic compounds (VOCs)
> Location: MX6 iBrid multi-gas detector - plug-and-play original factory replacement sensor module
Core parameters
| Detection of gas | VOC Volatile Organic Compounds (calibrated with isobutylene) |
| Ultraviolet lamp energy | 10.6 eV |
| Measurement range | 0 - 2000 ppm |
| Resolution | 0.1 ppm |
| T50 response time | ≤ 15 s |
| T90 response time | ≤ 20 s |
| Calibration gas | Isobutylene |
| Compatible host | Industrial Scientific MX6 iBrid (can only be installed in sensor slots 4# and 5#) |
| Expected lifespan | UV lamp under normal conditions approximately 18 - 24 months |
| Working temperature | -20℃ ~ +50℃ |
| Humidity | 10 - 90% RH, no condensation |
| Pressure | 80 - 120 kPa |
| Structure | Plug-and-play with PCB integrated module, can be directly replaced on site, and calibration is required after replacement |
Product features
1. The 10.6eV lamp can ionize the vast majority of common VOCs (benzene series, alkanes, alcohols, esters, etc.);
2. The MX6 host can be configured with **response factor RF**, converting the actual concentration of different organic vapors;
3. Diffusive intake, equipped with a dust filter membrane;
4. Not suitable for measuring substances with ionization energy > 10.6eV such as methane, ethane, etc.
Typical application scenarios
Enclosed spaces, chemical plants, painting workshops, oil and gas, soil remediation, hazardous waste warehouses, occupational health and safety EHS, environmental emergency detection, solvent leakage monitoring
Specifications:
| detection range is | 0~2000PPM |
| Accuracy | ±1% full scale |
| Working atmospheric pressure | 1013hPa ± 20% |
| Operating temperature | -10C to 50C |
| Working relative humidity | 0~99%RH(no condensation) |
![]()
Contact Person: Miss. Xu
Tel: 86+13352990255