Product Details:
|
| Material Model: | 10087913 | Compatible Devices: | ALTAIR 4XR / ALTAIR 4X / ALTAIR 5X |
|---|---|---|---|
| Input Voltage: | AC 100–240V, 50/60Hz | Output Voltage: | DC 6.7V |
| Charging Time At Full: | ≤ 4h | Charging Ambient Temperature: | 10℃ ~ 35℃ |
| Protection Functions: | Overcharge Protection | Overcharge Protection: | Temperature |
| Highlight: | MSA ALTAIR 4XR charger cradle,Altair 4XR multi gas detector charger,oil gas detector charging cradle |
||
Product Description:
YJJ MSA ALTAIR 4XR Charger Cradle for Altair 4XR Multi Gas Detector Oil
Features:
Compatible models: MSA ALTAIR 4XR / ALTAIR4 Four-in-One Multi-Gas Detector (LEL/O2/CO/H2S)
There are two types: **Single seat charging base (common spare part), Galaxy GX2 Multi-Unit Intelligent Charging Calibration Station. Below are the parameters of the standard single charging base.
Table
| Compatible Instruments | MSA ALTAIR 4XR, ALTAIR 4 Multi-Gas Detector |
| Input for Power Adapter | AC 90–264V, 47–63Hz, universal voltage worldwide |
| Output of Adapter | DC 6V, maximum 1.5A, power 9W |
| Safety Charging Voltage Um | 6.7V DC |
| Charging Time When Fully Charged | < 4h (from complete depletion, at room temperature 23℃) |
| Charging Temperature Range | **10℃ ~ 35℃** (charging is prohibited outside this range) |
| Charging Indicator LED | Red = Charging; Green = Fully Charged; Orange = Charging Failure |
| Battery Type | Built-in lithium polymer battery of the matching instrument |
| Important Safety Warning | **Do not charge in explosion-proof Ex hazardous areas** |
| Standby Feature | Automatically maintains trickle charge after full charge, can be continuously connected without power cut |
- Storage Temperature: -20 ~ +60 ℃
- Humidity: 5%–95% RH, no condensation
- Structure: Plastic charging base + contact-type docking, non-pluggable data cable, placement for charging
- Function: Only charging (GX2 model additionally supports automatic bump test, calibration, data upload)
Typical application
Maintenance spare parts, instrument charging and replenishment, on-site backup replacement accessories for 4XR detectors used in petroleum and petrochemical industries, mining, fire protection, sewage treatment, confined space operations, and factory safety inspections.
Characteristics
Original MSA compatible charging base, matching 4XR battery management chip, with overcharge and overvoltage protection
Wide voltage power supply, suitable for different countries' mains electricity worldwide
Status LED provides intuitive display of charging progress and fault alarm indication
Portable, suitable for centralized charging in laboratories, duty rooms, and inspection teams
Specifications:
| Hydrogen sulfide (H2S) | 0-200 PPM |
| CO | 0-1999 PPM (in increments of 1 PPM) |
| O2 | 0-30.0% vol. (increment 0.1% vol.) |
| Flammable gas (LEL) | 0-100% (LEL increment is 1%) or |
| Methane | 0-5.0% V/V |
![]()
Contact Person: Miss. Xu
Tel: 86+13352990255